  1. Garfeild

    ideal boiler wont fire up

    No the kids can't touch it,it'll have to be the service guy
  2. Garfeild

    Protecting external cooper pipe from theft..

    Wrap it with denso tape or paint it with the non drying paint
  3. Garfeild

    vaillant combi vcw gb 242 e Hot water problems.

    If you are the tenant,you shouldnt be worrying yourself,get the landlord to get it sorted pronto.
  4. Garfeild

    ideal isar

    :D
  5. Garfeild

    error

    What's the problem with changing them,it's not difficult is it?
  6. Garfeild

    glowworm ultracom 30 cxi

    He'll probably be back soon.
  7. Garfeild

    Glo worm betacom 30c problem

    Combustion Chamber on this forum,send in your gas safe details.
  8. Garfeild

    Ideal Isar hot water fault

    When you open the hot tap,does the boiler respond,as in display goes to "d",then diverter moves,pump starts,hopefully boiler starts. Does it do all or some of the above,or does it not even recognise the demand?
  9. Garfeild

    Ideal Isar hot water fault

    Theres a sensor,not a flow switch,does the boiler actually do anything when a hot tap is opened?
  10. Garfeild

    Vaillant Ecotec 831 noisy heat exchanger

    Call Vaillant they'll sort it.
  11. Garfeild

    Vaillant Issues

    Jeez,total abortion,have you paid yet? if not DONT.
  12. Garfeild

    Vaillant Issues

    How many radiators have you got?
  13. Garfeild

    Glow-worm FF50 Micron not firing

    Green flashing light is a lockout,MAY be pcb again,but could be the ignition probe,or the thermistor that goes in the top of the heat exchanger.
  14. Garfeild

    ideal isar he35 3 line fault

    L9 means a lack of circulation,possibly low system pressure (you have checked it havent you?) or pump failure. The 3 lines means its overheated as youve said,but you will have to switch of the power,then back on again to get rid of it,if it happens again,you will have to get it looked at.
  15. Garfeild

    isar HE30

    Its not meant to
  16. Garfeild

    ideal icos he24 fault code he

    Can be overheat stat,top right hand on flow,check compression connections above boiler,any leakage can run down,and get onto stat causing LE or HE faults.
  17. Garfeild

    Ref your post on ideal pcb.test on main feed to pcb which is top left 4 way connector As you...

    Ref your post on ideal pcb.test on main feed to pcb which is top left 4 way connector As you look at board,if you have 240v at connector,pcb IS knackered And is not repairable.
  18. Garfeild

    Ideal Isar HE24 problems

    Thermistors should be roughly 10k at 25 deg. But they are not your Problem Generally speaking L9 is lack of circulation/overheating poss pump Or ilack of system pressure,which I assume you've checked? Other than that,I recommend you get someone in to fix it
  19. Garfeild

    ideal icos he24 boiler broken

    Make sure the main electrical plug under the boiler Is connected properly I've had a few loose ones causing exactly the same problem
Back