Search results

  1. B

    pump fails to start

    hard to say unless your at the job. go to the fuse box and look for CH or anything close top that, if you have a mulitmeter check it. remember a neon can glow but it doesnt mean 240v is there. A pump needs that power to work. Take the tope of the pump off and smell it... if it stinks your pump...
  2. B

    quotes

    that is a very good price! alot cheaper than i would charge. Your friend of a friend give a price that sounds like a bit to cheap. The reason he might do it so cheap is maybe he bought a bargin off ebay or its a off the back lorrie boiler. I see people doing heating systems fully fitted for...
  3. B

    Mexico 2 Pilot light

    i charge £55-00 first appliance and £35-00 per add. So if you have a boiler and fire its £90-00 if you have a boiler cooker fire and another fire its £160 I love servicing conventional boilers i dont who told you that but its fine. Its only a flue test, vis inspection, stable flue runs...
  4. B

    Suprima pressure loss

    could be hard to find. I would install a new system if i was you and get rid of the suprima we repair them all the time there useless and expensive to repair. get a baxi 105 on a new system. you cant go wrong! the pipes under the floor proberly are not protected. run them on skirting boards and...
  5. B

    Baxi 105E boiler whistling when CH is on

    nope your not reading me right. Its a common fault on a baxi boiler i thought you might know that. although the heating runs it can cause a washer on the h/w to vibrate. When the hot tap is opened the washer stops vibrating which stops the whistle. I have repaired many of these and baxi had...
  6. B

    Baxi 105E boiler whistling when CH is on

    sorry about shocking spelling i am a little tired... :P :P :P :P :P
  7. B

    Baxi 105E boiler whistling when CH is on

    ahhhhhhhh! i was waiting for this problem to start again, i thought baxi sorted it as the baxi 105 boilers we fit are now not doing that The noise is not lime scale or anything! it is infact a small black washer. under your boiler you have chrome fittings. locate the h/w one and the...
  8. B

    Asbestos advice

    masona i would put my life on it its asbestos. why not take a small sample. call a chemist out, look under asbestos in the yellow pages for an analyst. ask him to come and do a sample. if its asbestos it wont cost that much to remove. it its not then your fine to tear it down.
  9. B

    Air

    oh i misunderstood you
  10. B

    No hot water, but CH works!!!

    your radiator problem could be sludge. Your boiler however can be many things... i cant seem to re-call that model number but on standard combi boilers like vokera 80sp and others, its always the micro switch or diapram. I have even found the arm to be stiff. But as for your boiler i cant...
  11. B

    Steam in expansion pipe CHeating!

    sorry when i mean blow and mean BANG! they 80% of time trip. i can understand how you though blow and suck were related LOL
  12. B

    Air

    the potteron kingfisher was first realesed around 8 years ago and my company were issued a kingfisher to install as a test boiler to replace the thorn. Unless your talking about the balanced flue then in that case your right. The rs came out about 8 years back and i have been fitting them for 8...
  13. B

    Steam in expansion pipe CHeating!

    the amount of calls i get explaining they have just had a flush out by a company and there system is banging is unreal. I hate flush outs they create more airlocks than enough. I aint a plumber but i am a gas fitter. Removee the BOILER stat, its a long copper coloured pole that goes in the...
  14. B

    Air

    Well i havent seen the job yet but i will be there on monday so i will give it a go. I get my corgi book through the post each month and nothing has told me about ripping out a gravity system and replacing with fully pumped on basic boiler changes. sorry but that sounds like stretching a...
  15. B

    Steam in expansion pipe CHeating!

    I dont see how the wiring can be an issue. It will already be wired back to the boiler. I really think you should try the stat thats ALL it can be i have worled on these for years
  16. B

    Steam in expansion pipe CHeating!

    It sounds like air. try pulling stat and wait for a splatter in the head tank. The pipes will get hot so watch it. The pump overrun would sometimes cause it but unlike the apollo it sounds like a basic air lock. Also the pump is supposed to run after the boiler shuts off but are you 100% sure...
  17. B

    flames escaping

    thats crazy. it should have been swicthed off long ago. flames should never be that condition and never even come close to escaping from a boiler. If its under poss pressure fumes WILL be escaping its just a question of how much damage has been donw. You cant smell CO2 but you will still get a...
  18. B

    Asbestos advice

    they cant be asbestos sheets, they will be superlux. asbestos is now illegal. Superlux looks the same but its safe!
  19. B

    Air

    this was just a replacement boiler. I dont think customers will folk out an extra £900 to convert to fully pumped. I will swap the pump over and put it on the flow. To be honest i always fit pumps on the return on kingfishers and profiles and never get any problems, however i dodnt fit this...
  20. B

    Dropping pressure on a worcester bosch 24cdi

    exellent, glad to hear it