    change shower on unvented system

    Just turn the mains water off and open the taps to release the pressure.
  2. S

    Combi boiler + pump + shower setup question

    It does sound like a viable setup, one which I've never come across before, however I think the problem is that the mixer shower needs to have balanced hot and cold feeds so putting a pump on the hot only will cause problems. You could put a pressure regulator on the cold to the shower I guess...
  3. S

    Ideal icos he15 boiler problems

    Hmmm so when I asked the question if the manual air vent is venting or sucking in when opened I would have thought that answered the blocked fill query ?? Plus the fact that at least one of the rads has bled through. yes it is possible that the the fill is fully blocked or even partially...
  4. S

    Ideal icos he15 boiler problems

    firstly you are a proper unhelpful bellend who is more interested in trying to pick faults on peoples advice rather than offer anything to help the situation. how about you show me where I stated that opening the bypass will shift the airlock. I stated that opening it will help and that is...
  5. S

    Ideal icos he15 boiler problems

    nice one Dan you have been truly helpful......just like a chocolate tea pot !!
  6. S

    Ideal icos he15 boiler problems

    Yeah basically just leave heating and hot water on and keep bleeding the rads and the manual air vent. Just a quick check though, when you open the manual air vent just check that air is actually being vented and its not sucking air back into the system. I would have hoped that everything...
  7. S

    Vaillant EchoTech Fault F75

    Excellent stuff but who the hell actually asked the question or are you still drunk this morning :roll:
  8. S

    What's this part?

    I think its a discombobulator :D what is it off ? I don't see how it can be leaking if its not attached to anything lol[/youtube]
  9. S

    HE combi boiler air problem

    If you're not actually sure what you're posting is factual then maybe don't post so you don't look like a dick !
  10. S

    HE combi boiler air problem

    I get the whole point of if you're not qualified then do not touch it however it is legal for a competent person to carry out gas repairs in their own home, although I suspect doing work on an appliance in a home you rent is a very grey area ?1?! Anyway I will say that if the boiler is...
  11. S

    Ideal icos he15 boiler problems

    Ok so the hot water issue is more then likely just an air lock. If you have a mixer tap on the bath then hold your hand over the spout to block it off, open the hot tap fully then open the cold and force the water back through the hot pipes. Keep your hand over the spout for ten seconds or so...
  12. S

    Domestic vs Commercial Boiler in large house?

    I doubt the gas meter would be an issue at all. Also need to take into account how many people are likely to live in the house, how many bedrooms etc. For me the best bet would be a top end system boiler with high output, each level zoned seperately and an unvented cylinder sized up to meet...
  13. S

    Fitting a Triton Bar Mixer Showers

    no further advice needed ! Make sure you put the hot and cold pipes the right way though lol
  14. S

    Combi vs systems boiler for the 6th floor flat

    Unless of course you live in a 8 bed 4 bathroom "flat" and require a worcester 42cdi with a flow rate of 17ltrs/min, then contrary to the previous post, fitting a combi should be totally fine. Ps. Good luck flueing it at that height lol
  15. S

    Positive head shower pump

    Are we talking twin impeller shower pump here ? Have you purged the water through correctly ? Try disconnecting the shower hose from the bar mixer and turning the pump on and off from the switch a couple of times.
  16. S

    bolier problem

    How long is it staying on for ? Possibly circulation problem caused by knackered pump