  1. L

    Mainsflow Thermal Store problem - Coil failed?

    Less likely to leak when hot, hot things expand. :-)
  2. L

    Pressure rising from 0 to over 3 bar when heating is on

    iirc the pre charge on the accumulators should be 1.5 bar greater that the HWS system working pressure. So if you have a HWS/CWS working pressure of 2bar then the 3.5 bar you had was correct. Also the accumulators are there to aid the CWS feed to the HWS and has nothing to do with the CH. I...
  3. L

    Mainsflow Thermal Store problem - Coil failed?

    5 litres per day isnt a lot matey so maybe you wont notice notice testing with air. Test with water and a guage over say 4-5 hrs
  4. L

    Mainsflow Thermal Store problem - Coil failed?

    no problem bud. In that case then i would imagine that you should see bubbles of some sort. However if it is a minute pin hole then maybe not. How long does it take to over flow from say 3" below the overflow? Narrowed it down to 2 of 3 possible faults now..
  5. L

    Mainsflow Thermal Store problem - Coil failed?

    Yes I know that the store is primary stored water lol. I an an istaller not a diyer. The only way the header can over flow is ball cock. Split/damaged coil or boiler stat. Forget about looking for air/ testing with air. You may never see bubbles as they could accumulate under the header...
  6. L

    Mainsflow Thermal Store problem - Coil failed?

    Sounds to me like your boiler stat may have failed and is bubbling over, or as you say the primary coil has gone. Can you isolate the coil and re- test or pressure test the coil? HTH Gareth
  7. L

    Unvented Cylinder - Summer Pressure Drop and Mfrs

    Ideally i would like to ensure that the hws main feed is in 22mm throughout the house with 15mm to basins/showers and 22mm to baths. Are you sure the MDPE is 20mm and not 25? We live in a 5 bed house with 2 baths 2 showers. 25mm MDPE piped as above. Its been a while since i tested but from...
  8. L

    Combi and domestic HW buffer vessel (domestic)

    Bit of an update. Boiler is all in and running. Fantastic bit of kit. Had to increase slope to 1.8 which is a little higher than i would have liked but hey!! cylinder is heated via the hws in about 10-12 mins so pretty impressive. I have sorted a control option out for the HWS circ pump...
  9. L

    UFH Prob

    Yeah I know that mate, what I am saying I that the pump is also suckin on the PRIMARY return as well which I don't think is correct.
  10. L

    Pressure rising from 0 to over 3 bar when heating is on

    When you try to repressurise. Does the system pressure rise rapidly from 0? It does sound like the expansion vessel. Drop the system pressure, a press the shreider valve in, do you get any water out at all? Turn the filling loop on and keep the valve pressed, your looking for water. To re...
  11. L

    UFH Prob

    Yeah the cold to the blender has a NRV in it. What I am saying is the way it is setup, the pump will also suck on the primary return. Doesn't seem right to me? Thinking fitting a NRV here.
  12. L

    UFH Prob

    all sorted mate, i altered the manifold so the pump pumps directly off the blender to the flow. Its running at 40 deg. Cust says the room is toasty now. What i did find was that with the setup he had too, was that the pump is now putting negative pressure (sucking) on the primary return...
  13. L

    Worcester or Baxi

    Baxi over Worcester any day of the week. I was a big axi fan but i must say, have a look at the Viessmann 200w with weather comp. Ive removed my Baxi and fitted on if these.... Top boiler
  14. L

    UFH Prob

    cheers for the reply mate, the cust laid the pipe himself, he said it was a 120m coil and used it all in the floor. Im going back tommorrow so ill fire it up again and get my return temp. I really dont think its gonna work tho. I recon it more like 180mm centres. Sorry i should have said...
  15. L

    UFH Prob

    Went to a job yesterday, cust says UFH stopped working. I cant see that it ever worked. 20m2 conservatory single loop from a blended manifold. He says it had 100mm kingspan in, 120m 16mm uponor and 130mm of CONCRETE over the top of it. It had a flow temp of approx 45deg. Also he said he...
  16. L

    Advise needed wrt gas pipe size.

    Where in the regs does it say this? I have spent the last ten mins looking trough my books and its no where to be seen. Excess pressure drop on an existing installation would be classed as NTC as long as all is working fine, however on a new installation i would be tempted to slap an AR...
  17. L

    C/H Expansion tank filling continuously

    Tie the ballcock up and run a hot water tap for 20 mins. See if the F and E level drops. Could also be a split DHW coil.
  18. L

    copper manifold

    You can also get endfeed 54mm fittings. Brazing is a piece of p155. Hire a set and have a little practice. 1 hr or so tops and youl be away.
  19. L

    Planning New Boiler an Rads

    My theory maybe wrong but it has always been my understanding that it is a good idea to have over sized rads at a lower temp for longer. Of course WC is the best option, but that isnt what the OP has asked for. I am more than happy to retract my theory's if im completely wrong, but it...