Search results

  1. W

    Solar panels,wind turbines and heat pumps

    EDIT heat pumps
  2. W

    Solar panels,wind turbines and heat pumps

    Do your customers actually get them fitted or do you think it`s a fad ? All seem very expensive with ridiculous payback times. How can i say to a customer solar panels are great ,but er.. it`ll be 10-15 years before you get your money back.
  3. W

    boiler flue?

    Er , nothing.Looks perfect to me! :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol:
  4. W

    Can you solve my Vaillant combi boiler problem, Sherlock?

    Cheers Grimly Ow`s about you givin me your address and i`ll send you a diagnostic bill? LOL!!!! :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol: :lol:
  5. W

    Boiler

    Surely it`s a wind up. As John McInroe says" you cannot be serious!!!!!" :lol:
  6. W

    Can you solve my Vaillant combi boiler problem, Sherlock?

    Grimly The diaphragm on your water section is knackered.It can be replaced providing the screws on the water section undo.Also change stuffing box as well.Your diverter valve is fine. The diaphragm has been the underlying fault all along.You`ve needed a far to high a flow rate to get...
  7. W

    Boiler not firing up

    doesn`t have to be fan flue version. Ddin`t they make b/f version of the profile? If so it could have the sit nova 820 gas valve on it.Solenoids on these gas valves breakdown quite a lot. paul 8)
  8. W

    Pilot Light On But Boiler Won't Fire Up (Vokera)

    blocked venturi i bet.can cause aps to stick midway between on/off.
  9. W

    GEM Combi boiler (imported by Combi boiler co)

    think motor on valve is standard synchron as on Honeywell diverter.
  10. W

    medway boiler

    It was the later super medway version Agile.
  11. W

    Can you solve my Vaillant combi boiler problem, Sherlock?

    Grimly Just read your OP and you said the flow was powerful-how powerful?.The flow rates for this boiler were not great -about 10/11 min approx. Was the water temp. defective before the dhw h/ exchanger replaced? The burner on these fire up at ignition rate then ramp up to full burner...
  12. W

    vaillant TURBOmax VUW shuts down

    No that`s the vcw 242/282.The stat is the c/h limit stat
  13. W

    Boiler not firing up

    Have you got 240v at gas valve?
  14. W

    boiler kettling on hot water

    you need to get dhw ntc checked to see if boiler modulates when stat turned down.Also get burner pressure checked as if way out can cause localised hot spots in heat exchanger breaking away bits of the primary h/exchanger reulting in noise-ie kettling.
  15. W

    Can you solve my Vaillant combi boiler problem, Sherlock?

    Grimly Things to check 1 Flow rate at tap. The new h/exchanger may be less restrictive than older model so give higher flow rate.I also doubt if your engineer changed the inside of the diverter valve and attended to mod to pcb.hopefully he did. 2 Gas pressure at burner...
  16. W

    medway boiler

    The diaphragm on these is held on by nut screwed onto valve stem.Have had several instances where the stem has snapped when i opened water valve up.Whoever does the job will have to be careful not to snap this stem when doing repair-provided it hasn`t snapped already.If this has happened new...
  17. W

    saunier duval isofast condens f35e combi

    I`d ask for a replacement boiler.They`ve had enough attempts to fix it.
  18. W

    Rated Tradesmen

    You`ll find all sorts of to$$ers trying to get hold of your money.spend as little as you need for advertising and try get work word of mouth.Local paper a start.At least your work will be local. Paul
  19. W

    heat sheilds

    not true.saw facia board that had come undone and fell onto flue which caused boiler to go off.
  20. W

    No Hot Water - Ferroli Medone 80E

    If the little led for the dhw does not come on then the first check is the dhw flowswitch and the filter into it. They do fail. I`ve even had new one`s straight out the box faulty. The switch can be stripped down and the shaft of the wheel greased. Paul
Back