  1. W

    Boiler fine but cold cylinder

    Some primatic cylinders have a little air vent fitted on the side about 1/2 way up.
  2. W

    boiler adjustments

    Then i stand corrected.Thought he had done burner pressure test but not gas rate cheack
  3. W

    boiler adjustments

    Mr Barker on an earlier post you said that if you have checked the gas pressure you shouldn`t really have to check the gas rate. ?? gas pressure has nothing to do with gas rate. Remeber the poor RGI who fitted a brand new flueless gas fire and didn`t gas rate it as thought it would be...
  4. W

    ravenheat rsf820/20 combi

    If the electrics to boiler are OFF then gas valve must be jiggered .see previous post.
  5. W

    Differing heat levels in Radiators &

    Sounds like air could be getting pulled in through open vent.Easy to check for.Or has pump been fitted wrong way round?
  6. W

    Empty Radiators

    And they keep me busy :lol: :lol: :lol: :lol: :lol: :lol:
  7. W

    no hw on alpha boiler

    diaphragm or switch on div.valve.
  8. W

    Maxol Homewarm 600 B/F Boiler

    If you remove the boiler case to effect repair you have to check seal on case after replacing .Have you got relevant equipment to check for spillage/effectiveness of flue. I doubt it .Job for RGI i`m afraid. If you try to diy and you make a mistake someone can get poisoned or even worse.
  9. W

    ravenheat rsf820/20 combi

    poosible gas valve gone faulty and firing up even though no electric supply.Boiler not worth repairing, throw in bin and get good vaillant/worc boiler fitted.
  10. W

    New Install to an old house , advice please

    I stand corrected. I don`t install just repair so forgive my ignorance. :wink: :wink: :wink:
  11. W

    New boiler. Hight Street or Back Street fitter?

    After having a discussion with 1 of our local corgi inspectors he told me: if a RGI signs off a gas installation done by a non RGI he will get a *******ing from Corgi and a letter from the HSE . The HSE are taking a dim view of anyone signing off others work. You have been warned...
  12. W

    Banging radiators

    When a rad starts banging go turn the trv upto the next number or 2 .Does the banging stop? Yes? Ergo, faulty trv or most prob fitted at wrong end of rad.
  13. W

    Hot water only heats radiators as well

    something else of which there could be several causes.
  14. W

    Advice needed for choice of new boiler

    maybe dhw stat faulty or gas valve not regulating properly.Easy to check if you use a decent RGI which there appears to be several who post here.
  15. W

    New Install to an old house , advice please

    I was at the "meet corgi" in Manchester last week. The guy from Worcester was there extoling the virtues of solar panels I asked him what the payback time was for a typical 3/4 bed. detached. His answer 10-15 years.He said it wasn`t really worth it for nat.gas. Personally i think all...
  16. W

    The law and TRVs

    Fit trv`s everywhere, as well as wind turbines,solar panels and heat source pumps.Oh and air con as well.Should keep everyone happy.Bloody regs!!!
  17. W

    servowarm heat exchanger

    How long since h/exchanger not available? Seems B.G may have been taking money off you even though parts not available for several years.
  18. W

    Gravity (non) circulation

    Empty F&E tank?
  19. W

    potterton netaheat electronic 6-10

    The back of these boilers are notorious for perishing due to little leaks where the pipes are connected to the boiler.If there is any signs of corrosion then the boiler could leak dangerous fumes into the room.DO NOT attempt repair if you not corgi registered.You could kill someone.
  20. W

    Keston C36 Jet Engine!

    first call your installer to check boiler is installed and set up correctly( not saying he hasn`t).After that contact Keston as it`s u/g