    Pluming makes a loude bang when switching on

    How long does the noise last? Do you get dhw and ch? Could be pump sticking. Need more info.
  2. W

    hot water problem

    low flow rate could also be due to blocked/restricted water filter on inlet to water flow switch.
  3. W

    ***Boiler Problems Baxi Combi Instant 105e ... Help Please**

    Baxpoti`s right.Have had these valves fall as well as some exp.vessels on the earlier models. Best left alone my advice.
  4. W

    central heating flow and return pipes

    not putting rad in conservatory are you? plenty of probs when installers fit big con. rads and have teed into 10mm supplies from nearest rad.Very common and very useless.
  5. W

    Baxi Bahama Playng up :-(

    C/h switch notoriously crap.usually find manifold where it screws in full of muck,
  6. W

    What does a new boiler & installation cost in London?

    Question for Polly.How much should llords be making from their tenants? Curious as you think we are all robbing swines.
  7. W

    Glow Worm Micron 80FF problems

    yes can concur pcb poo.Have changed original design now nice green colour.
  8. W

    What does a new boiler & installation cost in London?

    Most landlords are to$$ers.Peroid.They want a top notch job done for peanuts.Get real that aint gonna happen.You want quality then pay for it.So why don`t you the job done for as cheap as you can but don`come back hear whingining when it all goes tits up and you cant get the installer back...
  9. W

    ***Boiler Problems Baxi Combi Instant 105e ... Help Please**

    sounds like leaking from behind front section of water diaphragm housing( the diverter is split into 2 parts)If its leaking between the front section and rear the seal inside the rear has gone.
  10. W

    Worcester Heatslave 9.24 noisy and cutting out

    Boiler is most prob over 10 years old.DHW heat exchangers do get blocked up causing overheat stat on main heat exchanger to trip out pilot.fitting new pump and heat exchanger cost ££.Would advise too look at new boiler cos this one could cost you a lot of money long term.
  11. W

    On demand water heater not firing, help needed please

    you can still get diaphragms for these.They are the same as the earlier main medway.I`d get one while stocks last and also get pushrod o ring seal.Not a job you want to do yourself but good to have parts at hand.
  12. W

    Worcester 28CDI Intermittent Air Pressure Fault

    can you hear anything like relays chattering from pcb after being on for 5-10 mins..Had severeal go faulty on 24i range.
  13. W

    Another cold radiator

    Has one of the rad valves got a drain off? May be able to " drag" air lock out of pipes through it.
  14. W

    Central Heating Upgrades - Circulating Pump Location

    If you are concerned primarily with dhw temp then fit a 15mm cyltrol valve on dhw flow into cylinder. ( it`s like a trv for cylinders.)
  15. W

    Adjusting Pressure

    have got parts for these previously.Look under protherm for parts/mi.
  16. W

    Ravenheat DHW probs

    c/h sensor faulty.It acts as overheat as well.Could also be partially blocked venturi or faulty aps.Is heating going up ch pipes when on dhw.If so new diverter.Ravenheat cheap crap in my opinion.What i would class as a throw away boiler. remember if you break the case seals you are responsible...
  17. W

    Baxi Solo 3 PFL

    Have you got 240v on live at fan?
  18. W

    Central Heating Upgrades - Circulating Pump Location

    Altetrations wouldn`t prevent trv`s sticking.This wil be due to sludge in 20 year old system which will need flushing to remove.Personally i would leave system as is for now and when time / money permits rip out old boiler and drag system into 21st century.