Search results

  1. Echo the husky

    Problems with Hive - radiators not heating

    No electrician would install wiring like that, whether they knew about central heating systems or not.
  2. Echo the husky

    Boiler replaced not turning off after CH demand from nest has ceased

    That is not wired for Y plan, it looks like S plan. Y plan has a single valve, S plan has 2 separate valves. Assuming the system works properly with the old controller and all the wires in the loose connector blocks haven't changed, the nest looks like it is wired correctly. The black wire...
  3. Echo the husky

    Am I doing this right? 2 gang dim light switch wiring

    Don't forget to earth the metal plate.
  4. Echo the husky

    Pushfit

    I've seen plastic water pipes leaking from squirrels chewing through them.
  5. Echo the husky

    Am I doing this right? 2 gang dim light switch wiring

    That's quite a mess. I would recommend calling an electrician.
  6. Echo the husky

    Fluorescent batten starter

    I hate it, we chuck away loads and loads of failed LED fittings now, instead of just putting in new tubes and starters like we used to. The amount of within guarantee period replacements we do is shocking. I replaced 2 new fittings in an office before Xmas that had failed after 5 weeks! We have...
  7. Echo the husky

    Wire demister in room with dimmer switch

    The MK rollover dimmers were available years ago but not now and had a rocker switch that fed a dimmer and had the aux un dimmed terminal. Ideal for switching on the wall lights while being able to dim the centre lights. Tap Tile touch sensor switches also have a separate dimmed and non-dimmed...
  8. Echo the husky

    Mira Vigour shower, no powerful

    Did you fit the brushes correctly? Are they free to move in and out? Are any connecting wires properly connected to the motor? Is the motor buzzing/humming? Can you post a close photo? It might show possible problems.
  9. Echo the husky

    Happy new year

    Happy New Year from me also!
  10. Echo the husky

    LED Tape light caught fire

    The centre of the burn looks to me to be where a cut point would be, though it will hardly be heavily loaded near the end of the strip. Even if it was a poorly made internal factory join, I wouldn't expect enough arcing for a few small LEDs to start a fire. If the PSU can supply 100W that is a...
  11. Echo the husky

    Creda Comfortaire Replacement

    Yes we have repaired quite a few of these over the years and don't often have problems getting parts. Stuck a new motor in one last year. What is the fault with yours?
  12. Echo the husky

    Toilet water level too low

    A photo of the unit you have would help!
  13. Echo the husky

    Old A/B valve advice

    Yes, though if there is enough working room the pipework can often be frozen to save draining. Don't forget to replace the inhibitor if the pipework is drained.
  14. Echo the husky

    Old A/B valve advice

    Oh dear! In that case you will need to convert the system to use standard heating control components, probably to a 'Y' plan with a 3 port mid-position valve and a cylinder stat.
  15. Echo the husky

    Old A/B valve advice

    The system installed is designed with super efficiency in mind, the Hive much less so. The system will require substantial electrical and mechanical alterations to install. I'd recommend calling a heating engineer. (Or leaving it as it is!) The 'burn marks' are likely just dust drawn in from the...
  16. Echo the husky

    Old A/B valve advice

    Any photos? Might help explain what system you have.
  17. Echo the husky

    Removing a double socket

    Good vacuums those Dysons, just serviced one here. Incredible power for such a small size.
  18. Echo the husky

    Samsung Fridge Freezer

    Most Samsung models have repair kits available to repair this type of fault. If you do it yourself, make sure you fit every part supplied in the kit. There was a number of recalls for Samsung fridge freezers a while back, check your model and serial number is not affected Samsung were modifying...
Back