Search results

  1. Garfeild

    Shoddy work giving tradesmen a bad name.

    Laugh out loud And its annoying when some people seem to have to use it at the end of every sentence.
  2. Garfeild

    Ideal ICOS HE15 Error Codes LE and LF

    LE can also be a faulty overheat stat,on the Icos the oh stat is up near the top of the boiler,and if the connectors above leak water/crud can run down to the stat. LF is flame detection,as already mentioned.
  3. Garfeild

    Shoddy work giving tradesmen a bad name.

    i would be happy to try new ways,the crimping method appears to be a good way,particularly as many buildings now will not allow the use of naked flames,for soldering. Like many ive been a bit of a stick in the mud,preferring to use e/feed soldered,although i have used plastic and push fit...
  4. Garfeild

    Ideal Icos HE12 bubbling and banging loudly

    Sounds like poor circulation,check the pump,are all the rads in use,or have some been shut off,have all rads got TRVs on?
  5. Garfeild

    Ideal Icos Condensing boiler Fault Code LE

    LE can also mean an overheat stat fault,check its clean,no gunge in/on it,wires secure.
  6. Garfeild

    Isar HE30 air vent valve leak

    Its threaded,use a bit of grease to lube the new one as it has an o ring to effect a seal,it will leak if you dont wind it right in.
  7. Garfeild

    Saniflo bust, repairs?

    And a gas mask.
  8. Garfeild

    Isar HE30 air vent valve leak

    You have to remove the fan and burner,even then its not easy,use a pair of grips to remove it,and refit the new one,i made a special tool,cos i was changing them all the time, a sort of socket that fitted on the AAV perfectly,that made it easy.
  9. Garfeild

    Ultimate Heating System

    £1000 daily for labour !!!! youve been reading "The Sun" too have you?
  10. Garfeild

    the combi boiler explodes, and the plasterer dies

    If you think OPs post was good,which it was by the way,i worked a fair few years ago for the water company,there was a sorry saga invloving a shared supply which was turned off leaving a certain woman without water,it carried on over the course of a weekend with road gangs out trying to run temp...
  11. Garfeild

    Ideal Isar HE24 Fault

    Yes i think he must have sorted it now it was July last year.
  12. Garfeild

    Ideal Isar - Very Strange Problem!

    Not being funny, but if you cant understand this you really need to get someone in to look at it.
  13. Garfeild

    Ideal Isar - Very Strange Problem!

    Run a link between L1 and L2 on the main electrical connector to the boiler
  14. Garfeild

    3 way valve replacement

    Last year i changed about 6 Honeywell 3 port valves that were "clonking" there was a faulty batch apparently,which move too quickly causing a clonk which vibrates through the coil in the cylinder,and other pipework. In all cases,swapping the valve for a new one was a complete cure. Get them back.
  15. Garfeild

    Ideal Isar HE35 - DHW ok, no CH

    6 month old thread
  16. Garfeild

    Ongoing central heating /water problem tradesmen baffled

    THE PROBLEM IS NOT "NORMAL" It is your landlords problem to sort out,you have rights as a tenant,so dont be fobbed off.Withdraw payment of part of your rent until its sorted to your satisfaction,if its costing you a mint bacause of using additional heating,keep a detailed record of how much,then...
  17. Garfeild

    Isar HE24 no lights lights but still working

    Before buying new parts,check the connector hasnt come adrift.
  18. Garfeild

    gas fitter

    :D
  19. Garfeild

    Ideal Icos M3080 dismantling / opening instructions

    Yes it looks like its leaking from the sump joint,this is non repairable,and will need replacing. Ive started to lose track here, i thought you had a problem with the boiler making a noise to start with,and were calling Ideal out on a fixed price repair?
  20. Garfeild

    Ideal Icos M3080 dismantling / opening instructions

    Well if you rang up for a fixed price repair he should have booked it in to have the heat exchanger replaced,they should let you know in due course when they are coming to do it.