Search results

  1. E

    Boiler problem

    Thanks' Agile I have had a search around the forum and it seems the Thermocouple could be 'going down' , I did replace this years ago when the pilot refused to light I didn't realise it could work/not work when failing.
  2. E

    Boiler problem

    Thanks' ianmcd, the heating came on with the timer this afternoon as per normal and hot water seems fine so the pilot must have stayed lit the second time,would you still reckon on a pump/circulation problem ?
  3. E

    Boiler problem

    Hi all, we had no hot water or heating last evening so had a look at the boiler this morning (it's in the loft :( ) expecting to find the pressure had dropped and knocked out the pilot light ( vaillant vcw 240h combi ) but the pressure was only just under 1 bar but the pilot light had gone out...
  4. E

    Which wall coating to use prior to wallpapering

    Hi all, I am about to wallpaper one of our bedrooms and from previous efforts know the walls are not modern type plastered walls but a whiteish porous finish and a bit gritty :? the house was built in 1928 if that gives a clue to what the finish is. What would be the best coating to use to...
  5. E

    Vaillant VCW GB240H not working

    OK i'll try that then. :|
  6. E

    Vaillant VCW GB240H not working

    Hi, I have a Vaillant VCW GB 240 H it's about 20 years old and is not firing up, the heating was on and we were drawing off hot water at the time the boiler stopped working and it has not worked since. Four years ago I fitted a new diverter valve ( complete with switches),HX,and DHW...
  7. E

    Fence advice

    Hi, hope this info doesn't come too late ! I did hundreds of fencing repairs in the fifteen years i did in the fencing business and found the best method is to use concrete repair spurs, these are available in 3" and 4" section and are 3 - 4 feet in length. For your particular job use the 4"...
  8. E

    servis caress 1600A wont spin

    Hi,did you solve your problem ? I have the same machine with the same problem. ________________ lynda, moderator please note forum rules 17 & 20
  9. E

    Vaillant Combi

    Thanks weargas,thats interesting,i did see a black unit (bottom front) with copper pipes atached some i think went to the diverter valve and it had a spring on it,so i need to locate this pin you mention does the dhw microswitch start the pump?if not at which point does the pump start to...
  10. E

    Vaillant Combi

    Thanks everyone,a bit of a difference of opinion there then ! I do wish now i would have gone with my first thoughts and bought a new boiler,every part seems to cost £100 or more and a Ravenheat combi at B&Q is under £400. Anyway i havent give up yet,in for a penny mmmm. To answer weargas,no...
  11. E

    Vaillant Combi

    Hi,my vaillant combi stopped producing hot water recently and only leaving the hot tap on full for a considerable time would it work (sometimes).I would have replaced the boiler as it is about 12 - 15 years old but advice from this forum and pals at work persuaded me to repair rather than...
  12. E

    Choosing a Combi Boiler

    Thanks DP,I live in Bristol and from your comments I had better call in the repair man,I hope I can find a good un !
  13. E

    Choosing a Combi Boiler

    Hi,I cant boast of having technical experience like the guys above but i have had a Vailant Combi for 15 years ( a 240 i think ) in a three bed house and brought up three kids and all the washing and baths that go with em ! I have found the economy and conveniance of these boilers far outweigh...
  14. E

    Tiling on plywood walls

    Hi Mate,I had a similar problem after I extended the bathroom into the back bedroom to create enough space for a shower cubicle,I also used timber boards for the shower surround and mounted tiles on that.But being in the timber trade at the time I did know how timber would "move" due to the...
  15. E

    Vaillant Combi

    Hi,I have a Vaillant Combi VCW GB240h its about 12 - 15 yrs old.The problem is the boiler loses pressure over time ( about 7 - 10 days at the moment ) this has always been a problem since it was installed but it used to be every couple of months between top ups.The only part i have ever replaced...
Back