Search results

  1. T

    alarm bell box

    Evening all.. I live opposite a doctors surgery and when it is windy the alarm can go off randomly during the night at all hours.. I called the doctors and advised them of this and they called an engineer out who told them there was no notifications of the alarm being triggered.. Any ideas...
  2. T

    shower will not turn off

    I've had that changed before Dave and since had a filter fitted so I hope it isn't plus all other taps run consistently hot I.e baths, washing up etc
  3. T

    shower will not turn off

    Evening all I received a replacement shower cartridge for my Mira combiflow shower as the water was running cold after a minute or so..i took the housing apart and realised I wasn't going to shift the existing cartridge (tried with pump pliers and no joy) I put everything back together and now...
  4. T

    shower running cold

    3460250, member: 140646"]Cartridge. Andy Discontinued for my shower which is a mira combiflow built in to the wall is there any known alternatives that can be fitted or is it a new shower??
  5. T

    shower running cold

    Can you be a bit more specific lol
  6. T

    shower running cold

    Thermostatic
  7. T

    shower running cold

    Morning all System-combi sealed boiler - baxi 28he platinum fault - water from shower runs cold after about 1 minute. Water from all other taps runs hot and the heat is maintained. If I stop the shower and run the hot bath tap until the water is hot the shower then runs hot for another minute. I...
  8. T

    work in houses with no rcd protection

    yes the use of steel pipe was for cable protection not for decor :D I was trying to get round putting an RCD in and at the same time making sure that cable was mechanicaly protected
  9. T

    work in houses with no rcd protection

    I totally agree
  10. T

    work in houses with no rcd protection

    yikes just checked and seen the debate?? The reason I would install the RCD protection is for my own peace of mind so I can walk away from the job knowing that the work I have done i.e my cableif buried in the building fabric are up to current standards.. in this situation the customer isnt...
  11. T

    work in houses with no rcd protection

    never thought of a RCD FCU i was thinking of a 2 way RCD board but the RCD FCU is a much better idea the existing breaker is a MEM type 1 5amp 51QEB i might be wrong but i am sure i have seen this type of breaker in an RCD format that takes up two spaces in a board sure it was in a bill...
  12. T

    work in houses with no rcd protection

    i did mean the steel conduit would be buried in the building fabric not on show.. but as you say if its required to be rcd protected then i will mention that he will need a new board or a an rcd unit mounted alongside his existing fuseboard thanks
  13. T

    work in houses with no rcd protection

    evening all how do you guys approach work in domestic houses where there is no rcd protection ?? i have been asked to look at a job in a bathroom for a friend of mine he wants a heated mirror installing and a fan in the wall do you guys push for a new board or do you change the mcb...
  14. T

    Loft light not quite working as it should

    sounds like you have perm live in com and switch wires in a connector..so light is controlled by both switches... you need a permanent live and neutral and earth into a jbox then a permanent live switch live and earth from yhe j box to the switch then from the j box a switch live neutral and...
  15. T

    photocell

    yes the contactors are alongside the db.. didn't hear it kick in as was outside covering the cell.. we would normally stick a timeclock into this set up so the lights dont run all night.. the lamps are metal halides and the guts in the fitting contain the ignitor, capacitor etc.. on the new...
  16. T

    photocell

    yes its a doctors car park the lights are all the same from when our firm installed them 8 yrs ago..no individual photocells on...
  17. T

    photocell

    evening all I replaced a 5 foot lampost in a car park recently..the car park consisted of 9 lights broken down into 3 circuits all lights switched by a single photocell..before digging out the old post I covered photocell and knocked off mcbs 1 at a time to know what lights were on what...
  18. T

    moving a consumer unit

    Evening all in reference to the pic below.. My auntie has bought a house and the current set up is as below.. She would like the consumer unit moving out from the basement.. Am I right in saying the max meter tails is 3 meters from the cutout to the db.. Can I get round this by having an...
  19. Untitled

    Untitled

  20. basement

    basement