    32 amp
  9. T

    ikea electric hob

    Hi Customer has bought one of these all singing all dancing electric hobs with a rating of 7000 watts on max load..also bought a new cooker with a 13amp plug..current set up is a 6mm from the db on a 32amp mcb to a cooker switch (10 meter run) then down to a flex outlet plate, from the flex...
  10. T

    kitchen rewire

    Its going to be on the existing ring so I will have to rcd protect all cables
  11. T

    kitchen rewire

    Hi guys just after some advice.. Called out to see a customer who is getting a new kitchen..all plaster has been removed showing all cable runs some good some bad.. I explained id give him a price to add extra points and remove /re route cables into safe zones..he has an old fuse board non rcd...
  12. T

    ring final circuit

    So im newly qualified and want to run my ideas before a number of experienced electricians ahead of speaking to my boss to design the wiring...is this not the place to do it??
  13. T

    ring final circuit

    Dont mean to sound arsey but how many responses offer wiring suggestions...I suggest circuit into a spur supplyinf stop start then stop start back to contactor....ring wired through s contactor..if it doesnt comply then please advise if it does then can this method be improved
  14. T

    ring final circuit

    Ffs I havent just walked into the school and said I would like to rewire your classroom.. I work for a firm I am a recently qualified.. the spec is a ring final which is what we have to work with...the job is through the council the design is by an architect..we could ask for a radial but the...
  15. T

    ring final circuit

    only 1 stop/start is required to isolate all sockets
  16. T

    ring final circuit

    yes :wink:
  17. T

    ring final circuit

    the spec for the job is a 4mm2 ring main feeding about 8 sockets at workstations (its a science lab) they want the teacher to be able to isolate the sockets with a stop button inc a key lock and then be able to re energise with the start button..
  18. T

    ring final circuit

    Evening all Im looking to wire a ring main through a contactor with a stop start mushroom button that can be locked off with a key.. Im unable to download paint.net so ive created a drawing( a bad one) showing how I plan to wire this but would like to some advice/thoughts on how it could be...