    Baxi duo tec combi 28he boiler making loud noise

    toilet float valve, hearing noise when you tek a leak at night.
  2. B

    Isolation Valves

    most iso valves are not rated for central heating temps so should not be used.
  3. B

    Ideal Logic Heat 15 standard condensing not a combi - Intermittent F2 / L2

    logics are a very good boiler, only issues i found is following so called engineers who service them without even opening the case, this is the same with all other boilers aswell.
  4. B

    Best Plumbers in Birmingham For a New Boiler

    is it a combi for combi swap? to many things influence the cost apart from the boiler itself even if you had a not very good boiler like a vokera....... gas upgrade, powerflush, controls, filter, flue system, condense route etc......
  5. B

    15 mm connection for P&T valve

    why not get your installer to decide what to use? and only a halfwit would install his own unvented cylinder.......
  6. B

    Best silicone? (for bathroom)

    mapei is far better than 785. I use 785 for general stuff and mapei for finishing
  7. B

    Gas feed pipe for new fire.

    Get it routed into opening feeding pipe from rear
  8. B

    Auto Bypass

    The system needs an auto bypass. Get him back to fit one.
  9. B

    Powerflush diy

    Did the powerflush take all day? What chemicals were used? What pre and post survey paperwork was left? British gas won't guarantee much after powerflushing but they should do a proper pre and post survey at least. Sometimes the only solution is to renmove the badly blocked paperwork.
  10. B

    Is there a maximum 15 mm pipe length from the 22 mm ring?

    one pipes are fine on modern boilers although not ideal. no need to rip the lot out. more important to get the right vavles and balance system.
  11. B

    Moving a gas pipe

    no idea of what hourly rate you would pay, remember an hourly rate is normally based on a full days work. you will need the gas safe engineer to disconnect the hob if your changing the worktops/ kitchen which will involve another visit.
  12. B

    Valiant EcoTEC

    if the vessel just needs recharging then the cost should be 1 hours labour. this can be done on an annual service so maybe book a service if it has not been done in last 12 months but tell the engineer theres a pressure loss issue.
  13. B

    Servicing/cleaning central heating filter with no ISO valves

    attach a washing mac hose with other end into a 2ltr pop bottle. may save you cleaning dirty water off the surrounding wall.
  14. B

    Need to lose back boiler but can't have a flue! Ideas opinions pls

    you def cant fit a vertical flue to a roof terminal?
  15. B

    Valiant EcoTEC

    tell her to ask the engineer who does the annual service to check it out. as above its possible an expansion vessel, prv issue. if she has not had it serviced for a few years it probably needs an important seal changing.
  16. B

    Central Heating won't turn off!

    get a heating engineer in to check it, if its a boiler problem and not a control issue then call out manufacturer under warranty.
  17. B

    Replacement for Baxi WM 40/4 PF

    ideal logic heat only has rear flue option. no pump over run also.
  18. B

    Radiator not centred between pipes

    just measure the distance of the current tail on the right, divide it by 2 and get two tail extentions that size and refit. may have to alter the brackets. speak to council sparks about the bonding being reconnected.