Search results

  1. B

    Quote for new consumer unit and cooker point

    120 a day is subby rates around my parts, 150-180 normally for private work 200 should be the min really. the price seems good to me, no body on an internet forum can tell you really what the job should cost. id rather somebody have the time and wage to do there job correctly then rush it. the...
  2. B

    Charged to fix contractors work

    if it was my job i would have charged for the cooker install and not charged to repair the leak. Hopefully its been fitted correctly, over half the cookers i fit i have to move the pipework, bayonet to the new cookers instructions, supply a bracket or chain, sometimes hose so id def have charged...
  3. B

    bath, basin, toilet different whites!

    they will never be exactly the same shade as they are different materials. post pictures so we can see. Ive fitted alot of IS stuff and never though it was a different white to other makes. your bath is a good choice and the sanitary a decent make.
  4. B

    New flat immersion heater melting wires

    you should have guarantees with the builder both for a limited time for such things as plumbing and electrical and for 10years on structual. Even if the guarantee period has gone a company is still liable for work done that was done incorrectly or unsafely. For example if a plumber fits a tank...
  5. B

    non concussive taps

    id be shouting at bristan while my customer had me around the kneck :)
  6. B

    non concussive taps

    thanks for the reply. ive fitted these types of taps before but not with such a low pressure and although i can find them rated at 0.2bar min pressure i dont want to shell out the money fit them and find ive got to fit normal taps afterall. Ive been asked for non con but i dont want to promise...
  7. B

    What is a Venturi please

    isnt it a pet detective?
  8. B

    Worcester-bosch service contract exclusions

    What is done on a service is down to the manufacturer really, although BG and others will probably say different. Apart from the general checks whats is required depends on what is found. If you explain its not been serviced for a while and you want a service and all important seals and probes...
  9. B

    New flat immersion heater melting wires

    the builder should be sorting this out. Dont take no for an answer. It seems strange you got an imm with a stat that did not have a cut out, this is against the regs and should not have been fitted. Get hold of your electrical test cert and contact the electrician who wired and tested the house...
  10. B

    non concussive taps

    anybody fitted single non con basin taps when the head of wata is only around 0.1-0.2 bar? and if so what taps did you fit and did they work?
  11. B

    Too many rads off 15mm pipework?

    without seeing the system most engineers would advise on the increase in pipework size. 15 can feed 6-10kw depending on many factors which thoses with brains and a need can tell you about.
  12. B

    heating pipes opposite side of joist to hot and cold

    most importantly the cold needs to be kept at a low temp for health and condensation so along as the energy in the heated pipework does not heat up the cold it should be fine. If the runs are quite long then lagg them.
  13. B

    Unvented Cylinder Location

    no, the discharge pipework can be routed under floors, inside walls but it must have a fall. check out building regs part g and cylinders manufacturers instructions. the discharge pipework must terminate in a safe visable location at low level to be safe.
  14. B

    Gas cooker

    if its on a hose you can disconnect it, but it would be better to get the connection either tested to ensure it does not leak or better still blanked off so she can not reconnect the hose when your not there.
  15. B

    Joining brass to plastic piping

    you should look into a Eco boiler grant, somebody on here may be abloe to advise you about them.
  16. B

    Gas Meter box full with water

    ill tell you how it works on new builds. The company installing the main does not fit the gas box the builder has to have it fitted before they arrive. The builder does not want to pay the plumbing contractor to fit it so its not part of the plumbing contractors package. Then the site agent will...
  17. B

    Soil Pipe Vent Full of Water

    on new builds its quite common for the svp to vent to a tile vent, you just hope the tiler puts it near the stack ive had to run 110mm about 6m before then connect flexi to tile vent. the way you have it now should be fine if its securely fixed.
  18. B

    Boiler issue - suspect good cleaning required and advice needed

    what is the size of the pipework to your radiators?
  19. B

    Ideal boilers

    they are alot better, the vogue is very good. they have had a few issues with hex leaks but get fixed under warranty most makes and models have a period of specific problems, same with cars and many other things.
  20. B

    Condensation in Bathroom

    you may find that before your paint allowed your plaster to absorb some moisture and now its sealed over with new paint, that and the fact this winter seems alot worse then normal for condensation. well it seem it in my house.
Back