Search results

  1. U

    External Insulation DIY - questions

    I've seen a couple of designs on https://retrofit.support/ they use woodfibre insulation, two layers by the looks of it, and the window frame sits inside the first layer. A ply/softwood box goes in the old window hole to cover the existing brickwork. specifically looking at this setup...
  2. U

    External Insulation DIY - questions

    tomfe, open to suggestions at this stage, window inside the insulation is possible - if the window can fix within 100mm, and the window can fix securely to the insulation board, or i can engineer something to sit in the insulation for the window to attach to!
  3. U

    External Insulation DIY - questions

    Thanks for the responses, In terms of windows, this is the bit that is confusing, some people say do windows first, some say after. I'm now thinking do them both at the same time - so put boards on the wall, fix window, render boards! Re above - there is a walkway which is mine - approx 1m...
  4. U

    External Insulation DIY - questions

    I am looking to do a DIY External Wall insulation project, but have a couple of questions. The house has solid walls on three sides, the rear has a new ground floor extension. The rear of the house backs to an open field so gets brunt of wind. The side of the house is to an alley way, so not...
  5. U

    Sloping ground-Rear extension

    In my case, i had approx 500mm underfloor space in the existing part of the house, so dropped the entire floor level down for the connecting room. This gives impression of a high ceiling, but nothing majorly out of place.
  6. U

    Rad getting hot with hotwater

    Images of the front, back and pic of manual... I'm guessing he's done as image shows, but instead of ufh manifold he's done rads. Manifold would not heat if zone doesn't need water, but rads will if no thermostatic valves!
  7. U

    Rad getting hot with hotwater

    So I turned on Ch only for upstairs noted what pipes got hot and in what order. So zone valve opened and pipe got hot, followed it and it led to the hot water tank bottom connection(middle of three) The back of the tank has two outputs, of which the top of the pipe got hot, which then went...
  8. U

    Rad getting hot with hotwater

    thanks dp - need to get decent view of what pipes are going where to try and see whats happening. I suspect that the flow or return for rads is passing though the HWT for some reason, but once ive got a camera on a stick or wife's compact mirror on a stick i can see which pipes at the back...
  9. U

    Rad getting hot with hotwater

    Thanks DP: My tank has a total of 8 connections. At the top, i have cold in, hot out, and a white expansion tank. At the back i have 2 22mm connections (They go towards a section of the tank i can not see). At the front i have 3 22mm connections (again they go towards a section of the tank i...
  10. U

    Rad getting hot with hotwater

    I think the NRV may be the easiest option, but i need to correctly identify the pipework for the HWT first, cant see why i would have 5 sets of 22mm for rad circuit, unless it is plumbed in to the rads somewhere. Could be that the return for the upstairs rads could be via the tank to take up any...
  11. U

    Rad getting hot with hotwater

    One image showing the pipes to the front of the tank, top one as far as I can follow (it passes behind the tank so can't be 100% sure but am 99% is from the zone valve. Bottom two disappear behind the tank as two pipes on the front, but there are 5 at the back, which should be flow/return for...
  12. U

    Rad getting hot with hotwater

    Gas112, boiler and tank were replaced along with install of ufh in Dec, so this is the first summer that I've noticed as the heating was suppose to be off...
  13. U

    Rad getting hot with hotwater

    To clarify, it is all rads on that zone - one in particular but it has been balanced that way (coldest room so i've got it set to get hotter then the rest). Agile- All the pipework on the tank is 22mm, save fresh water feed/return at the top of the tank. DP - I'll check tonight
  14. U

    Rad getting hot with hotwater

    So i confirmed my initial flow/returns, The same sides get hot for CH as they do with DHW. I looked at the return pipes and their order of connections, last one before filter and boiler is UFH manifold... and i cant see where the return is for the upstairs rads! The hotwater tank in use is ACV...
  15. U

    Rad getting hot with hotwater

    Thanks for comments guys, Didnt get a chance to look this weekend (In law's moved in to the main room that's heating up but will aim tonight to check which ones are heating with CH as DHW was already checked). Will also try and figure out the return pipes and which ones are connecting in what...
  16. U

    Rad getting hot with hotwater

    dp, thats exactly what i am doing, except i don't get enough time to wait for the pipes to cool back down before i could test the CH side yesterday, and the room was well over 28 at about 7pm without the HW heating the rad, and trying to get my kids to sleep isn't easy with that heat... I've...
  17. U

    Rad getting hot with hotwater

    I checked the rads that are coming on with hw on, so will try ch this weekend (dont really want to make the room any hotter then it already is!). Agile, any guidance on what order? The other thought i've had is my HWT has ability to plumb the output from the tank into a feed for UFH/other...
  18. U

    Rad getting hot with hotwater

    I know the flow/returns on the rads are mixed in the sense of TRV's on 2 are on the return, one is on the flow, and one has two lock shields so there is a plan later in the summer to change all out, was thinking if i need to make any adjustments at the zone valve ends i can do it at the same...
  19. U

    Rad getting hot with hotwater

    Good Morning, With the recent heatwave we are experiencing, i've come to realise that the radiators on my 1st floor (seperate zone), are warm/hot even when the heating side of the system is set to off via programmer. I think i've pinned it down to the rads are getting warm when the HWT is...
  20. U

    Old wiring on new CU?

    I like what I'm hearing, now just need to got hold of a spark that is willing to do that rather then push for a full rewire. Historically the two cu's were possibly on peak/off peak as it had an eco 7 meter, but since I've owned the property, everything has been on and off at the same time...