    fuse board makes

    hello sparks, Is HAGER a decent make fuse board and how does it compare to MK
  2. G

    Vaillant EcoTec Pro 824 Modulate Heating temperatures?

    is it a 824 or a pro 28, also is this the new design for 2012
  3. G

    new vaillant pro 28

    hi all, I have fitted my first new vaillant pro 28 over the weekend, has anyone else had a issue with the CH not coming on to main burner. I phoned vaillant and the said take the boiler out of auto on the D settings. when i rated the boiler at 24kw it seems to work ok but there is still a 10...
  4. G

    new house no paperwork

    Thank you for the replys, i have been working away so thats why i'm on here now. The cost implecations don't really matter to much, i was going into the purchase with the intention of a rewire anyways. my main concern is my tenants safety and covering myself with paperwork. I am glad that the...
  5. G

    new house no paperwork

    thank you for the reply, visually the work looks tidy clipped ect. i know legally i do not have to get the electrics tested but for a one off cost it is piece of mind for me. Does the EICP carry out all the relavent safety checks like , earth loop - rcd times - polarity ect Would they...
  6. G

    new house no paperwork

    I Have recently purchased a house to rent. After i gained access to the property i noticed that the fuse board if new and the cabling colours are brown and blue. on my paperwork i noticed "electrical alteration work since 2000 -no" The question i would like to ask is what check should i have...
  7. G

    help - Bell Box to contol panel

    that helps a great deal mate, hopefully the alarm works because some ***** ripped my old bell box off the wall and blown the fuses inside the unit thanks again for the help
  8. G

    help - Bell Box to contol panel

    hi - need some help with connecting kinetic Az-teck external sounder unit to my control box. I am unsure of the make but the pcb is made by networker the connections on the bell box are 1/tamper return 2/bell(-) trigger 3/supply 12v (+) 4/ supply 0v (-) 5/strobe (-) the connections on...
  9. G

    Boundary’s

    cheers for the replie
  10. G

    Boundary’s

    Hi need some help with boundary’s, I live in a mid terraced house. The neighbours house protrudes out more than mine…..I have had a porch built on the front, the porch roof carries on for about 5m on a 8"-3" beam and rest on a joist hanger which is fastened to the neighboursing house. The...
  11. G

    electrics in rented property.

    I am getting a second house , which is completing next month. Is it advised / needed to get the electrics checked to rent
  12. G

    electrics in rented property.

    I am getting a second house , which is completing next month. Is it advised / needed to get the electrics checked to rent
  13. G

    electrics in rented property.

    hello, Whats checks and paperwork do i need in a rented property? Do i have to have hard wired smoke alarms?
  14. G

    Earth Bonding On A Worchester Combi Boiler

    You don't need suplanenry bonding if you have a 17th edition consumar unit. If you have any other consumar unit then it is adviced. (best practice)
  15. G

    Glow Worm 18hxi - Airlock circulation issues WITH SOLUTION

    yh i would agree, alot of jobs look like this now tho thats why quotes are cheep the person who installed the boiler must have moved the f&e because it was bodged ontop of the cold water storage tank.
  16. G

    Under Floor Heating

    i am not the best with underfloor but here goes it should be zoned and run at a constant low temp you best await other replies tho as others are better informed
  17. G

    LPG - acs change over

    As you can tell i live in birmingham I have been in the gas ind for 12 yrs since left school, i have only ever worked on natural gas but after working beside a LPG rgi i am thinking of doing my acs change over What do You think - also whats the correct procedure for a tt on bulk and...
  18. G

    Glow Worm 18hxi - Airlock circulation issues WITH SOLUTION

    more than anythink the system would not work due to air bleed the middle screw of the pump in the loft- put a old towl under and alow all air to be removed the boiler model you have has a overheat switch inside the boiler that has to be manual reset. (i would agree if it is a...
  19. G

    Is this my stop valve???

    yes it is your stop tape- need not mention it requires replacing
  20. G

    Glow Worm 18hxi - Airlock circulation issues WITH SOLUTION

    it looks like from the pipework layout it is a bungalow. the pump in the loft can cause a issue with air being drown into the system and also the distance the F&Etank is to the boiler. Raise the tank in the loft