    I think it is time I changed this boiler

    Oops, me bad, my documents are 2002.
  2. G

    I think it is time I changed this boiler

    I disagree, bedrooms minimum practise, all best practice.
  3. G

    House bought off British Gas Engineer has noisy new boiler !

    no one's perfect. Probably expansion/contraction of pipes against a floorboard.
  4. G

    Oil Boiler Replacement...

    I do. So you think because i'm CORGI I am not qualified to fit oil boilers, in fact I have my OFT101/102/600a, which in my book says you cannot install tanks or oil supply, and no, I am not OFTEC registered, don't need to be. Incompetent people install/repair and service gas boilers as...
  5. G

    Draining combi system

    The valve in your picture is a lockshield, with a drain off.
  6. G

    Oil Boiler Replacement...

    I don't see it like that Dave. OFTEC cost £169.20 per year and they want it five years up front, and you have to be re-assessed every five years, plus the fact that it is voluntary unlike CORGI. It costs me just £2,400, including lost time, every five years for Corgi re-assessment, how do...
  7. G

    Boiler stuck on won't switch off

    If it is a combi, then a faulty micro switch.
  8. G

    Oil Boiler Replacement...

    Someone has been telling porkies then, I think they are just another bunch of money grabbers and I will hold out till I have no choice or they lower their prices, they also lead people to believe that certain manufacturers will just give you a £250 voucher towards your registration, but that...
  9. G

    Boiler Flue

    I would agree that the left hand side would have been a better option, however the OP said it was his request. Whilst I would endeavour to to advise my customers with possible options at the end of the day it is their choice, and with your attitude, I would'nt be surprised if the customer...
  10. G

    Advice Please

    Being a member of any of the many organisations that are available to us is no guarantee of the competence of any individual, they all have there own complaints procedure.
  11. G

    not enough mains pressure to run water heater

    No, if you want to increase the pressure of the hot water from the cylinder, then fit a pump on the hot water outlet, to balance the supplies, take another feed direct from the cold water tank and use a twin impeller pump.
  12. G

    not enough mains pressure to run water heater

    If you already have a cold water tank, then you only need a cylinder with an immersion heater, nothing magic about it.
  13. G

    Oil Boiler Replacement...

    To join OFTEC at this point in time is a matter of choice, i.e voluntary, just as it used to be with CORGI, but now we have to be CORGI registered.
  14. G

    not enough mains pressure to run water heater

    You could use a combination cylinder, the top section is cold water that feeds the bottom section, which in turn is heated by an electrical element.
  15. G

    Oil Boiler Replacement...

    For how much longer though, is another matter.
  16. G

    Oil Boiler Replacement...

    OK, I'll rephrase it, they do not have to be OFTEC registered. :lol:
  17. G

    Oil Boiler Replacement...

    No you don't, you need a competent person.
  18. G

    adding a rad

    You could also have a primatic cylinder, if not a sealed system.
  19. G

    Moving Combi

    What can't be moved.
  20. G

    valiant pressure on 3.0

    The filling loop is letting by. The expansion vessel is knackered. The divertor/diaphragm/water valve is worn. Just to start you off. More concise information would be useful