  1. RF Lighting

    DD GR10q 4 pin LED

    I forgot to ask - are your existing lamps 16W, 28W or 38W?
  2. RF Lighting

    DD GR10q 4 pin LED

    First question - do you know if these fittings have an electronic or a wire wound ballast? do they all have a replaceable switch starter? Also are any of these fittings combined emergency lights?
  3. RF Lighting

    EICR unsatisfactory, am I being ripped off?

    That seems like a rather blanket statement. The EICR presented by the OP seems like a reasonably decent report.
  4. RF Lighting

    Gu10 led

    No. It will leave a cold spot above each light where condensation will form and rot your roof timbers and plasterboard.
  5. RF Lighting

    Recessing a light pull switch into plaster coving

    Are you planning on setting the surface back box into the coving but actually attached to the ceiling? Can't see a problem with this apart from how neat you can make it look, but that's purely up to what you're happy with and not an electrical concern!
  6. RF Lighting

    Swa in garage

    I would agree that 32A is fine. 40A will just scrape through with 0.5% VD to spare but not ideal as your compressor will have a reasonable inrush current upon start up
  7. RF Lighting

    Recessing a light pull switch into plaster coving

    I've recessed pull switches before. A round dry lining box works well as a back box. You have Schneider (formerly GET) brand switches which have BESA standard fixing centres and will screw straight into the box. Not sure why you would need a hammer for this?
  8. RF Lighting

    Swa in garage

    It depends on the supply type to the other containers, but it could be right that they have all been done incorrectly. 32A supply fuses and TT earthing and a local RCD does sound like the proper way to do things.
  9. RF Lighting

    Moving consumer unit more than 3 metres from meter

    For a standard 2/3 bedroom rewire we used to get sent with 200m 2.5mm² t&e, 200m 1.0mm² t&e, 100m 1.0mm² 3c&e and 50m 10mm² earth and we’d normally have some bits left over at the end. I’d say the average domestic ring is between 60 to 80m long.
  10. RF Lighting

    Recessing a light pull switch into plaster coving

    Do you need separate switches for the light and the fan or could they come on together? Could you move the switch(es) further in to the room so the strings aren’t in the path of the door?
  11. RF Lighting

    Shower question

    Is the bare (may be in earth sleeving) earth wire in your shower cable a single solid core or 7 smaller strands twisted together?
  12. RF Lighting

    What does this instruction on my thermostat back plate mean?

    The switching of your thermostat happens across terminals 3&4. What ever voltage you connect into terminal 3 will be outputted by terminal 4 when the stat is calling for heat. It is normal to have a 230V output on a standard heating system.
  13. RF Lighting

    Smart mcb?

    Yes I agree with you and I would imagine there will be high current rated WiFi switches and contactors available, but it’s not something I’ve ever really had much involvement with so I don’t know quite what is out there!
  14. RF Lighting

    Smart mcb?

    Aah I missed that. I’m still not sure if I believe them though...
  15. RF Lighting

    Latching or non latching RCD for Garage door opener?

    I’m not aware of any type of non latching RCD other than an RCD socket so I ass-u-me that the “waterproof RCD on the garage roof” is a weather resistant socket which the door opener plugs into. Perhaps some pictures would be useful here.
  16. RF Lighting

    Smart mcb?

    I don’t see any BS or EN markings on that device so it is not suitable for use as a circuit breaker in a UK installation. I guess you could have it installed after a proper circuit breaker in a separate enclosure adjacent to your consumer unit if you desired.
  17. RF Lighting

    Latching or non latching RCD for Garage door opener?

    I thought the garage door opener was plugged into a weather resistant active RCD socket?
  18. RF Lighting

    Grounding an Appliance

    I would rather the licence fee be abolished altogether and let the BBC become either a commercial or subscription based model just like every other TV channel in the world. I can’t remember the last time I watched BBC TV yet I still have to pay for them if I wish to only watch the subscription...
  19. RF Lighting

    Latching or non latching RCD for Garage door opener?

    If the RCD is tripping purely because you have a rural mains supply which suffers frequent power cuts rather than there being a fault with your installation which is causing something to trip then all is ok. I think a few people have misunderstood what you were saying. The only difference...
  20. RF Lighting

    Smoke alarm replacements - mains powered (+batt backup) vs batt-only

    Aico all the way. I’ve fitted hundreds and never had any problems with them at all.