  1. B

    minimiser se 60 - failure to light

    Thank you, i'll try and get hold of someone tomorrow, to give it a good servicing !!
  2. B

    minimiser se 60 - failure to light

    I have a problem with my boiler, its a ideal minimiser se 60, as soon as the burner light, lights up it switches its self off again and then repeats this process approx 5 times before stopping. It was absolutely fine yesterday ! Does anyone have any idea's as to what it could be ? whether or not...
  3. B

    Question for BAS or anyone with knowledge !

    Cheers BAS, sorry I dont have a lap top to compare !! you lot must be charging too much !!
  4. B

    Question for BAS or anyone with knowledge !

    The fire alarm is a ' proper system' with smoke heads, pushes etc etc on its own 1 gang board in another part of the building feeding a lcd display control unit, the system is around 12 months old and I believe was fitted by ADT but not 100 % on that, Do you know of any decent dual boards or...
  5. B

    Question for BAS or anyone with knowledge !

    circuits are as follows 1x cleaners socket in corridor 2x corridor light circuits (dont know why) 6x ring ( 1 each room) 6x light circuits (1 each room) 2x radials to office 1x boiler 1x officce lights 1x outdoor/welcome lights The place is already wired so its only fuseboard...
  6. B

    Question for BAS or anyone with knowledge !

    Sorry nosparks there is 20 rooms in total ( just pointing out the size of the place ) the board im talking about supplies 6 rooms, an office and a shed.
  7. B

    Question for BAS or anyone with knowledge !

    Garymo, is a disclaimer/ responsibility acceptance acceptable ? or would a court deem that the electrician shouldnt leave something, that relies on a bit of paper to get him out of trouble - if you see what i mean -
  8. B

    Question for BAS or anyone with knowledge !

    It has 20 rooms if that helps, what is the definition of an ' instructed person' my regs book is outside and im in my pj's ? I thought instructed by an electrician - again im probably wromg !![/u]
  9. B

    Question for BAS or anyone with knowledge !

    I was under the impression that with a supervisor on site that RCD protection was not always required - Im sure thats the way they told me at my 17th upgrade course - along with ' basically treat everyone like idiots - because most people are when it comes to electric ' - am I wrong ?
  10. B

    Question for BAS or anyone with knowledge !

    Ok well its only a thought I was having the other was dual boards which I know square d make,(but maybe not 17th availiable yet) Yep I know that RCD's not needed but, after discussion with owners they liked the idea of total protection - also staff live in this building all year round...
  11. B

    Question for BAS or anyone with knowledge !

    I may need to apologise in advance for this when someone with better knowledge than me reads this !!!! I am looking at a job fitting a new board in a hotel ( small B+B) They currently have 2 boards running from 40 metres of 16mm twin and earth, split in a henley between both , We are slowly...
  12. B

    storage heater board

    hi, im fitting a fuse board thats only for storage heaters, The supply to the house is brand new and after the main fuse there is a 4 pole isolation switch. Can I fit a fuseboard that has an rcd for a main switch and use the 4 pole isolator as the main switch isolation ? - which would obviously...
  13. B

    Square D rcbo qoe

    Nope, thats the new style, the one i need is quite old, coded 'QOE' thanks anyway :)
  14. B

    Square D rcbo qoe

    Hi, Does anyone know where i can purchase a square d 10 amp qoe rcbo, ive tried ebay but could only find one for £98.00 !! I dont want to pay that much !! TIA
  15. B

    17th Edition conumer units

    Thanks spark123, sorry didnt mean cheap as in ' cheap ' but best value for money. I'd love to fit all RCBO's but its just too expensive for customers. I wonder if these will start to drop in price now ?
  16. B

    17th Edition conumer units

    Although I havent had to connect up a new style board yet I have a few questions on how to !! 1) all lights on one, all power on other ? 2) any others eg smokes on rcbo ? 3) what if smokes are connected to lights ? should that whole circuit be on rcbo ? 4) should the kitchen be on rcbo...
  17. B

    bs3871 zs value ?

    thank you both very much for your replies. Do you recommend easy cert ? I currently hand write all my test certificates, however i'd like a more proffesional system. Can I use these with Elecsa ? or do i need an elecsa logo on test sheets i produce ? (im registered with elecsa )
  18. B

    bs3871 zs value ?

    Ive been told there isnt a type b, but it says B32 on it !
  19. B

    bs3871 zs value ?

    Can anyone tell me the zs value for a bs3871, 32 amp, b type mcb ? or where it is in the 17th, cos I cant find it !!
  20. B

    electromic starters - flourescent fittings

    Thanks RF, Are there any websites etc availiable that i can use to compare energy usage eg. if a factory uses 25 normal flous and i replace the with 25 high freguency flous taking into consideration the cost of the fittings how long would it take to redeem the cost and start saving ?