    Worcester Highflow 400. No central heating . Hot water ok.

    Easy way for this, switch everything off on the timeclock, put HW stat to zero and wait for the pump to stop over running. Switch on CH....does the pump run and the boiler fire for a short period, if so clock and external room stat is working. Diverters are problematic, never had the...
  2. S

    worcester 350

    The non return valve in the CH pump may be passing slightly. Are the rads heating up and do you have poor hot water?? If not then leave well alone!
  3. S

    BAXI Barcelona woes

    Is the inner combustion door seal ok and the door tight.?? They were orginally white and broke up then caused the products to leak locking out hte boiler on the fan stat. New ones are red, and much better. This is however getting past what a DIYer should be doing however as this is...
  4. S

    Glow Worm - no-one can fix...

    Could be the gas valve thats buzzing, The other thing that they have missed is dirt in the pilot flame which is very common on these boilers and also the elctrode itself mihgt be cracked or dirty. British Gas will do you a fixed price repair for £180 - £200 dependant on location. The...
  5. S

    Baxi Bermuda 552 Expansion pipe

    If the pipes are in the correct configuration ie, flow pipe from the boiler should have the exp pipe then the cold feed and lastly the pump as close as possible to the boiler then suspect a blockage in the cold feed exp pipe area. Needs to cut out and replaced.
  6. S

    baxi 105e no hot water

    not when you are not disturbing any gas components or disrupting anything to do with the combustion. Changing the DHW diaphram is a nice easy one to do for a starter.
  7. S

    Worcester 24i poss. PCB gone!

    surley not if the fan is not running? I take it you have checked the overheat stat on the top of the boiler has not popped???
  8. S

    wocester 24i junior combi boiler

    It wont cost you £50 because its only yesterday someone was out and you still have the same problem. Change you contract from the homecare flexi to the full buhna and it will cost you a little more over a longer period with no call out charge
  9. S

    Magnaclean

    take some pictures of where the boiler is in the garage, I might suggest that its better than in the airing cupboard. They can go anywhere in the system apparently tho!
  10. S

    Potterton Suprima Hot Water OK, No Heating

    I assume you have the room stat turned up?? If so then the fault will lie with you head of the 3 port valve, when on CH only you should get 240Vac to the motor in the head. If you do and it does not motor then its the syncron motor thats dead and easily replaced.
  11. S

    radiator valves..which is which?

    Locksheild on the return and the control valve on the flow, if its TRV's make sure you put the flow of water through the TRV the correct way.
  12. S

    Vokera 20-80 RS Flowmatic - Gas Pressure - Help!

    And watch he does not break the little brass screw in the middle as the modu reg is no longer available for these boilers!!!! Keep the instructions handy for the eng!!
  13. S

    AIR/CORROSION IN A CH/PRIMARY SYSTEM - HELP PLEASE

    what is the question of the assignment you are writing?? :-D
  14. S

    cold rads upstiars ??

    system will need balancing. Water will always go the easy route, if the rad valves are fully open downstairs then water will be shooting round these nice new rads. Shut the hot rads locksheilds down to half and make sure the cold ones are fully open, also after this turn off all rads...
  15. S

    Worcester 28CDi Increasing Pressure

    sounds like a pinhole in the DHW HE. Pressure riseing when all is off and no CH or DHW water being drawn. Its an easy one to do, just follow the manf instructions, drain down both HW and the CH water,a screw and a clip, and a nut, plastic bag over the drop down panel to save the...
  16. S

    I have a leak in my new central heating system.

    could be the the PRV or the heat exchanger leaking internally and its running down the condensate drain. Bag over the PRV and then disconnect the condesate from the bottom of the boiler and put a bucket under it, DO NOT run the boiler like this though!!!! signs of water in either will show...
  17. S

    Solder joints under a gas fire(place)

    I thinks he may be wrong (although I may be corrected), first time I have heard of not being able to use an 'appropriate fitting' to make a gas pipe... only place you cant use certain joints would be a compression where it is not accessable, i.e under a floor
  18. S

    Magna clean - is it required for a totally new system?

    Flow = High throughput Pressure = Force you can have a 5 inch pipe with huge flow and zero pressure, or an 8mm pipe with huge pressure and low flow. So no...flow does not indicate good pressure! However at 30 ltrs per min then it does sound fine!! Magnaclean is a must!!
  19. S

    Magnaclean quote

    A magnaclean is an excellent product and benefits any system whether is has a plate H/E or not. The symptoms you describe ie. cool rads and cold at the bottom will not be solved by adding a magnaclean, this product is a prevention measure and not a solution to poor rads. A flush and...
  20. S

    TOP TIP - Y Plan motorised valve actuator

    This tip works for s plan systems too... I have never gotten just a new switch tho, just butchered a new valve and use inline connectors, then kept the motor for another repair.