    Texecom Premier 24 - exdous 0h/4 smoke alarm

    Hi Sparky Yes, it's on it's own zone but wanted to use the latched input to the smoke alarm so as I disable the alarm the smoke alarm LED switches off too. On the texecom vertias system there was s SW+ output which could be programmed for this and I'm guessing the digi outputs can also be...
  2. G

    Texecom Premier 24 - exdous 0h/4 smoke alarm

    I've attached a smoke alarm to my texecom premier 24 but wanted to configure a latched output onto the panel as digi output 1. I've configured the smoke alarm as a fire zone and normally closed. II'm able to successfully trigger the fire alarm but unable to reset the smoke alarm using the...
  3. G

    Texecom Premier 24 not arming

    Only late yesterday evening did I managed to resolve the issue!! I was waiting for the USB comm cable to arrive and am I glad I bought it since it's so much easier to set-up and resolve issues. The main issue seems to be that I needed to 'confirm devices' though I thought that was somehow...
  4. G

    Texecom Premier 24 not arming

    I've ordered the USB com cable. I'll look into the com 2400 and that would be great if you could phone into it.. cheers, will keep you posted
  5. G

    Texecom Premier 24 not arming

    Everything defaulted and no messing with suites :) Manual is downstairs and couldn't remember the correct option/setting.. no more mentions suites :P
  6. G

    Texecom Premier 24 not arming

    yes, full reset. reload NVM settings Thanks for the info I did check the zone setup and checked that zones 1-2 were setup in area A. Set the arm suite to timed. Used Master user to arm the panel but once again nothing no error message/s on the control panel.
  7. G

    Texecom Premier 24 not arming

    Ok, thanks - I did place a resistor which then showed unused zoned as secured but still were unable to arm the panel. Will order another panel and test again. Thanks
  8. G

    Texecom Premier 24 not arming

    No, no com2400 connected. Do you see the unused zones as active?
  9. G

    Texecom Premier 24 not arming

    Update.. Phoned tech support but still no luck in arming the panel... No real issues from the discussion - therefore I assuming its an issue with the board. The most interesting point was that I had disabled Z3->Z9 (not used) but when arming the alarm and selecting omit I could still see...
  10. G

    Texecom Premier 24 not arming

    Tried no luck. The control panel never indicates that the system is alarmed though it registers a 'YES' when arming the system.
  11. G

    Texecom Premier 24 not arming

    Thanks Jibbeh, but no luck Reset system Changed exit mode to 'timed set' (areas... arming modes) Switched off the unused zones 3-8. Since I only have PIR's I've changed both to guard. ---> Turn off the 'locked by timer' options for the master code (setup users...User 01 Master....)...
  12. G

    Texecom Premier 24 not arming

    Double Pole/EOL Its is a 24 software version: v2.09.01 LS1
  13. G

    Texecom Premier 24 not arming

    Yes.. from one zone wired to the tamper. The other tamper has an 2k2 resistor wired across to the alarm terminal. The alarm terminal has a 4k7 resistor across both alarm terminals and then to the other zone terminal. thanks for taking the time to help http://isyn.co.uk/photo_01.JPG
  14. G

    Texecom Premier 24 not arming

    Wired using two wires with an EOL resistor (as the manual)
  15. G

    Texecom Premier 24 not arming

    I've updated the Suite Arm Modes and changed to Timed Exit but still no luck.. When arming the alarm I only get a single beep and thats it. The PIR's light go active but no sound on the control panel but if I lift the lid up I the tamper works as expected. I've not mapped any zones.. Is this...
  16. G

    Texecom Premier 24 not arming

    Unfortunately I'm not using the WinTex software... maybe I'll order the cable on-line. I'll check the manual and find the option/s to set it accordingly. Thanks for the help, very much appreciated
  17. G

    Texecom Premier 24 not arming

    I seem to receive one exit tone but that's it not sure if should receive a few until the 20 seconds are up. The tamper lid is disabled until I sort this out but if I open the PIR's the tamper alarm goes mad on the control panel.. probably as the same with the lid I expect, will give it ago...
  18. G

    Texecom Premier 24 not arming

    I'm just starting a install of a premier 24 alarm system but cannot trigger the alarm system from the PIR's/ I've only installed two PIR's (as a start) and the walk in test show that these two PIR's are fine.. secure and active wired correctly.. all good so far. When I arm the alarm and wait...
  19. G

    Texecom Veritas Excel control panel tamper light

    Resolved.. :) Control Panel lid was not closed properly causing the tamper light to be permanently on. This was found by performing the walk through test that highlighted the zone at fault and then by pressing the omit button indicated the cause...
  20. G

    Texecom Veritas Excel control panel tamper light

    Thanks John, unfortunately didn't work.. Do you know if I defo need an external sounder for the system to behave?