  1. flameport

    Surge protection?

    Not only are those things unknown, they will never be known.
  2. flameport

    Surge protection?

    Surge protection is recommended for most electrical installations. Plugging in a random adaptor which claims to have surge protection of some kind will achieve very little.
  3. flameport

    Swapping out old heat only boiler, so many choices

    A combi boiler will tie you to gas forever, as all heat pumps and other electric heating options require a hot water cylinder. Combi also means zero options for using solar power for hot water. If two cylinders are not required, delete one of them. The existing boiler is 2x larger than it...
  4. flameport

    Gravity or Pumped?

    This relay needs to be in an enclosure to avoid live terminals being exposed.
  5. flameport

    Legit MS Office?

    MS Office for nowt is obviously a scam. It's all subscription based now anyway. Best case you might get some volume licensing key which could theoretically work for a while in some circumstances until it doesn't. Groupon in general is not necessarily a scam, but it's used by companies to...
  6. flameport

    Earth question - Shaver socket

    It doesn't. Rated 200mA, no time specified. The only reference to 'continuous' is that: The current-limiting device shall permit 200 mA to be carried continuously. It also states: These socket-outlets are not necessarily suitable for the supply to electric dry shavers containing battery...
  7. flameport

    Now it works, now it doesn't

    Very likely, it will disconnect the supply when it's hot. Cooling will take a while, some might need to be switched off for an extended time before they will work again. Also very likely. Things do not repair themselves. Change the lights to LED ones. Those halogen lamps and the transformer...
  8. flameport

    How much rewiring each side of meter on fuse upgrade 60 to 100

    Who 'needs' this upgrade and why? Dig up the road and sections of the driveway, front garden and whatever else is in the way. Or just change the fuse. Depends on what cable is already there,
  9. flameport

    Electric towel rail in Zone 1.

    Not required and hasn't been for decades, and even when it was back in the 1980s, the regulations for doing so were based on entirely wrong information.
  10. flameport

    Correct wiring for extractor motor

    Only with the details of the wiring from the manufacturer or whoever designed it. The colours and numbers mean nothing on their own.
  11. flameport

    Adding another light “gang” to my bathroom lights

    No. Members of schemes can only notify their own work. There is supposedly some 'third party notifier' effort that NAPIT did or possibly still does provide, but it was a pile of junk which pretty much no one signed up to and would be far more expensive and time consuming than just paying a...
  12. flameport

    Help with LED strip lights

    That thing outputs AC for an obsolete halogen lamp. The LEDs require DC.
  13. flameport

    Assumptions - BTU Estimators

    Anything still using BTUs is decades out of date and should be ignored. Same for anything that makes assumptions about what walls might be external or not. Some rooms don't have any external walls.
  14. flameport

    Ascertaining the age of a light switch

    Looks like Tenby, and probably 1980s before they were obtained by Legrand.
  15. flameport

    What is "Smart" central heating?

    In most cases, 'smart' anything is a solution looking for a problem.
  16. flameport

    Repairing kitchen worktop behind sink

    There is no repair. That could be done but some of the tiles will need to be removed at the back as that style of sink as a small upstand at the back which tiles go down to. A new worktop.
  17. flameport

    Temporary capping off a live cable

    This: https://www.tlc-direct.co.uk/Products/DEBOX2.html or something similar on the end of the cable.
  18. flameport

    Consumer Unit options preping for upcoming work

    Network supply and the meter must be moved at the same time, which will involve the DNO and your energy supplier. Moving your consumer unit can be done at any time. If the supply is moved elsewhere you will need someone to install a suitable switchfuse and a cable from the new supply position...
  19. flameport

    SP to DP Wylex RCBO swap

    Entirely untrue. To obtain cheap rates for electric vehicle charging with Octopus and others, the requirement is to have an electric vehicle, and in some cases an EVSE and/or vehicle which is compatible with their systems. Who installs the EVSE is unrelated.
  20. flameport

    Pen tester detects voltage from iphone charge

    Is that a proper Apple charger purchased from Apple? Or some knockoff piece of junk from some other source?