  1. S

    Riello rdb burner

    Your gassafe! But can’t check capacitor. Not difficult. Remove red burner cover capacitor is attached motor. Very easy to check.what else have you tested?
  2. S

    Avanta Remeha plus 24c not starting

    the fuse can be replaced. The part is available.
  3. S

    Glow Worm 18R mind of its own

    You can do the same with Vailliant version. Vailliant also have a kit available. Warranty is still valid if just 3 wire for either Vailliant or Glowworm using the Ali hex. Stainless ones have to have pump overrun
  4. S

    Boiler Frost Protection

    my guess is that the frost stat has not had the front dial put on in the right place. might say 5 degrees but is probably coming on at a higher temp. check pipestat but reduce to 15 degrees. it also need the wiring altering. the froststat and pipestat arrangement should be altered so that it...
  5. S

    Glow Worm 18R mind of its own

    read page 28.
  6. S

    Glow Worm 18R mind of its own

    this boiler can be wired up with switched supply/power. it is not the preferred method as fault codes etc don't work.
  7. S

    Help with Greenstar 8000 Life 35KW

    Easy heat is deciding what flow temp is required to achieve room temp. As room gets closer to target temp it reduces flow temp
  8. S

    Rought cost to replace an expansion vessel

    You can only work on unvented cylinders if you hold a current G3 qualification.
  9. S

    Worcester Heatslave Pil Boiler

    i would go with, 1, air in slave tank 2, flow switch sticking 3, diverter head/valve sticking
  10. S

    Unable to set hot water temp on Glow Worm 25r

    the boiler you have is a heat only boiler. unless you have glowworm smart controls fitted then the hot water function is not used. ( this control panel is used on the combi version boiler as well). the boiler only uses the heating temp. it uses controls to decide whether it heats the hot water...
  11. S

    Unable to set hot water temp on Glow Worm 25r

    your hot water temp will be adjusted either on the hot water cylinder or on the controls. what controls do you have?
  12. S

    Comment by 'snb' in media 'IMG_20201030_112853346'

    Filter setup for 2 pipe arrangement doesn’t allow for air release. Each pump should have an separator or the return lines should go back to the tank. Unless I’m mistaken it looks like the return lines link back to the flow lines.
  13. S

    Full Bore connection for water softener

    https://www.screwfix.com/p/jg-speedfit-plastic-push-fit-straight-tap-connectors-15mm-x-2-pack/85257
  14. S

    New Home Struggle - Vaillant Ecotec + Drayton Digistat

    Are you sure the boiler is still heating when stat turned down ? The boiler has an overrun after stat satisfied which keeps the pump running for up to 5 mins.
  15. S

    Underfloor Heating - Flow meter issue

    Looks like you have automatic flow balancing actuators. You need to make sure you have the correct sensor attached from each actuator on the flow and return pipe work from the underfloor. You also need the flow controls to be set fully open. The actuators are designed to adjust continuously to...
  16. S

    Honeywell problem baffled plumber

    Turn the fused spur off to the central Heating for 20 seconds. Turn back on. Then turn the dt92e down to 5 degrees. Leave for. 1 min and then turn up to 30 to check heating comes on. If it doesn’t then it needs rebinding as per instructions
  17. S

    Megaflow - insufficient hot water amount

    how big is the cylinder? and how long are you showering for? some of the newer showers can use 18 to 20lt/min water. the drencher types can be nearer 25lt/min so a 200lt cylinder with a mix of hot and cold would only last 15mins or so Max. people are always in a shower longer than they realise
  18. S

    Remeha Avanta Plus 28c stuck at code 8

    Just because the flow and return temps are same doesn’t mean the pump is pumping loads. Fairly certain it is pumping continuous around the dhw plate with the actuator in the wrong position. But it could be pin stuck or actuator wet as these are prone to leaking. On code 8 it thinks it has...
  19. S

    Remeha Avanta Plus 28c stuck at code 8

    when it is in code 8 you will have the fan running and the pump. it is doing that. points towards the diverter valve stuck in hot water position. take the actuator head and check that the pin moves up down. guess its stuck down in hw mode