Search results

  1. U

    internal concrete floors/lower exterior dpc

    the first one is a pic of what happens on the interior of the chimney breasts but it gets much worse after a while
  2. Untitled

    Untitled

  3. Untitled

    Untitled

  4. Untitled

    Untitled

  5. Untitled

    Untitled

  6. Untitled

    Untitled

  7. flat

    flat

    flat damp pics
  8. U

    internal concrete floors/lower exterior dpc

    the council are responsible for the structure then i have to pay half of the costs for repairs to them, but as you know council workers are not very skilled so they would get sub contractors in and give me a hefty bill, so i choose to get the work done myself, ie for the council to change the...
  9. U

    internal concrete floors/lower exterior dpc

    i have bought ex council ground floor flat in a converted house and the council must have concreted the ground floor throughout and my problem started with damp and white powder at about 8 inches above ground level also the plaster beading is showing rust marks coming through the walls, around...
  10. U

    new render, areas still seem wet days after rain has gone

    i have just had some large areas of render replaced and when it has rained parts of my render seem to dry out and some areas seem to be still damp as though it has not dried at all, what could this be, also should i paint areas with stabilising solution or anything else before tyroleaning and...
  11. U

    tyroleaning parts of already done wall, newbie

    Tyrolean Flicker Gun can i use just sand and cement mix because i had a bag of snowcrete stuff for it but it has gone off and i cannot find any now so will sand and cement do if so what ratio do i use and what type of sand, also do i need to pva or prime the walls or put any waterproofer in the...
  12. U

    ravenheat condensing boiler making noise earlier now code 01

    before i started all seemed ok with the boiler and the condensate pipe was connected via a grey clasp thing that cuts a hole into the 40mm waste that was fitted to go outside, but since the sink and bath waste were connected via a tee into this waste pipe also things started to go wrong and the...
  13. U

    ravenheat condensing boiler making noise earlier now code 01

    is this the pipe that runs away from the boiler through the wall to outside, if so i have also joined the bath waste and sing waste via a tee to this so they will all run out together, it has happened since these were fitted but wether it is connected or not i dont know as i am not a plumber
  14. U

    ravenheat condensing boiler making noise earlier now code 01

    the manual says, check condensate drain if is not blocked check gas valve operation check the fan starts check ignition control boards and cables
  15. U

    ravenheat condensing boiler making noise earlier now code 01

    i have a ravenheat condensing boiler, it was making a clunkimg noise earlier then straight after a quick bubbling water noise and now it keeps cutting out when i try to turn it on it trys to start but shuts out and the code 01 comes up on the digi clock any help please.
  16. U

    new ravenheat boiler keeps showing up as overheating

    thanks for your reply i wont want to tell him his job but i will mention these things to him and any other that may come as it could be (hopefully) a small thing like that that has slipped his mind
  17. U

    new ravenheat boiler keeps showing up as overheating

    yes he is corgi and i do have his number on a form i will need to fill in, are :lol: corgi registered plumbers stupid if they cannot find a fault, obviously you know whats wrong then? come on tell us then stop keeping secrets
  18. U

    new ravenheat boiler keeps showing up as overheating

    having new ravenheat condensing boiler fitted but when its being started the number 04 comes up on the digital clock and the book says its overheating although its only been turned on for about a minute, engineer says he has tried but cant find whats wrong, any ideas please
Back
Top