  1. chivers67

    Pre EICR thoughts ?

    Sewage treatment works haven't seen the main incomer yet just had a quick recce to see previous test records (from 3 years ago) yesterday which appear to be non existent! BTW I tested a socket ZS on Three Low off this and it was 0.42 about 4 meters from the board
  2. chivers67

    MCB Failure or something else ?

    Place one test probe on Earth and one on the Live and you should get 230v on AC . I don't think you can get an RCBO for that? might be able to get a longer bus bar and modify the board. Take the cover off carefully and take a photo of the whole board. buy yourself a proper non contact volt stick...
  3. chivers67

    Pre EICR thoughts ?

    Thoughts ? I've posted this on another forum but although this is a DIY some of you guys are pretty knowledgeable. Got to Test this next week. The board looks to have a modified incomer, what concerns me the most (not for testing) is should any kind of fault occur to this board and the RCCB...
  4. chivers67

    Waco connectors

    Are you able to access the ceiling void from above? Or fit one of these Wago inline box if there's a big enough hole where the cables come out the ceiling?
  5. chivers67

    Fuse keeps blowing

    Depends what's terminated & how in the Dining room switch, somethings shorting out.
  6. chivers67

    Fuse keeps blowing

    The next thing to do it take off the Dinning room light switch and upload a photo to see if there's anything obvious on that part of the lighting circuit. You may have to disconnect the Earths you re-terminated to determine whether with them removed the light works and fuse doesn't pop. Have...
  7. chivers67

    Wire in pendant light

    Does the new light just hang from the Rose? If so take the black cable out of the box you were holding and connect the Brown wire to the Blue/Sleeved switch live on the right of the Rose and the Blue to the left had side neutral block. It might look a bit odd with a black cable coming out the...
  8. chivers67

    Running Power to Shed - Advise Please?

    Is that including all the Labour burying it and back filling etc or clipping it to a wall that does sound a tad expensive for one circuit but could well be a lot of work. How far is that run? Maybe get two more quotes but times ticking, so I'd perhaps put a duct in and rope it before the Shed...
  9. chivers67

    Electric Oven Install

    What cable size is the circuit on? They'd be no need to lower the Fuse, the Oven shouldn't create an overload current that high unless there was something seriously wrong and if it did the 13A would blow if you're using a Plug for it?
  10. chivers67

    Running Power to Shed - Advise Please?

    No not really unless the SWA is terminated correctly then it will not meet regulations, as EFLI has stated this isn't really a DIY. Suggest you look on you tube Consult an electrician, any SWA requires the Armoured part to be Earthed (at least one end best practice both ends) so needs to be...
  11. chivers67

    Help please with outside ring floodlight cam

    Has the light switch got a Test switch of some sort to switch it on overriding a PIR ? Did the Ring not come with instructions? Would have thought the wire in one goes to L and one Neutral to Neutral and the other wire just put on a Choc block or Wago
  12. chivers67

    Problem with Bathroom Extractor Fan

    Is the Feed to the transformer ok? Any loose connections? Sounds very frustrating!
  13. chivers67

    RCD trips (Ed.)

    This could be caused by a Number of issues. Often it's caused by Water Ingress, with the fuse off check to see if there is any water present on the circuit. Is there a fused connection unit feeding the boiler / under floor heating? Are there two separate ones for each or one for both?
  14. chivers67

    FCU and outdoor socket

    Do you mean just removing a back box knockout and drilling out through the wall?
  15. chivers67

    Lights wired to socket

    I think Sunray has answered my query - looks like there may have been storage heaters in the property on Economy 7 at some point and now the five storage heater FCU's may have been changed to single sockets?
  16. chivers67

    RCD-protected circuit that is not on a separate breaker

    Hi Tony, I think so, As per Flameport's comments - If every MCB is switched off and both RCDS off and the only way of powering down that socket and Vent-Axia Fused Spur is by the Main switch then it sounds like a secondary cable is feeding that circuit and does require investigating.
  17. chivers67

    RCD-protected circuit that is not on a separate breaker

    Those are MCBs not RCDs. If all those MCBS FED from the 63A RCD are off it must be being Fed from an MCB something to the left of the RCD shown - can you try those? Can you post a photo with all the MCBS in the board as looking at the photo it looks like you have a dual RCD board? N.B. Might...
  18. chivers67

    RCD-protected circuit that is not on a separate breaker

    I'm not entirely sure what you mean in Q1. circuits 6,7,8 & 9 are FED from the RCD by the looks of it. Doesn't the MCB circuit 6 B32A power that double socket and vent-axia? Q2 - can't see a problem could sit right next to the other one if that was moved a couple of inches to the left
  19. chivers67

    Lights wired to socket

    The board looks like it feeds four socket circuits on the right via b16 MCB's not on the RCD protected side which looks a bit odd. is this a normal house?
  20. chivers67

    Lights wired to socket

    The light switch requires re-terminating as you can see bare copper on one of the terminations. If you do decide to install a sunken back box you may find you'll need to fit it at least a couple of inches above the surface mounted box as where it is you may find it difficult to plug equipment in...