  1. D

    Pyronix enforcer v11 control panel, how to turn off completely?

    Well it’s fair to say I wasn’t expecting that. I won’t start offering advice on EMF radiation from home systems - each to their own. Your only complete power down option has already been explained, isn’t really designed to be done frequently, will be a pain in the backside and also likely...
  2. D

    Pyronix enforcer v11 control panel, how to turn off completely?

    Understanding why you would want to do this would be helpful for the right advice being offered
  3. D

    Changing batteries in Pyronix Enforcer alarm

    Couple of things could happen…. You reset it fine. It asks for engineer reset or it asks for an anti code. Middle one is your only problem. In a domestic install if an engineer has turned on a tamper reset then they are at it lol
  4. D

    Changing batteries in Pyronix Enforcer alarm

    Defaulting a bit excessive if you don’t want to change any of the settings before knowing whether restore on tamper is set. Try and change the batteries and see what happens. If you can reset with your user code and are happy with the setup you already have then your all good
  5. D

    Pyronix Cloud passwod

    Just follow the instructions
  6. D

    No fused spur

    I’d also personally loop into the lighting circuit if you can with any new install rather than into a sockets ring main providing the unit isn’t going to draw too much
  7. D

    Virgin Media Landline

    Be good if you can come back to us with the outcome and what solution VM put in. Regardless make sure you are happy with their proposals.
  8. D

    Virgin Media Landline

    I was assuming it’s a cordless phone and it’s not plugged in to the modem in the attic and it’s the distance between the base and downstairs that’s causing the connectivity challenge.
  9. D

    Outdoor PIR pet "immunity" (Pyronix XDL12TT-AM)

    Appreciate the frustration but you’ve mounted the kit way too high. That’s what’s causing the false alarms. Would it be a big job to drop the cabling by a half metre to metre?
  10. D

    Pyronix enforcer

    Doing a full reset seems overkill. Can you go into change inputs on the engineer mode and put the info of each logged input into a reply here Also go into site options > exit modes and post what the exit mode is set as for A and B
  11. D

    Pyronix enforcer

    Was everything working before you changed something in error? You can fully reset the system settings either deleting or keeping the PIRs attached to the panel or alternatively we can try and resolve step by step.
  12. D

    Pyronix enforcer

    Just change the setting back that you changed in error What is the actual problem you have?
  13. D

    Pyronix alarm homecontrol 2.0 error

    Is your router running dual band?
  14. D

    Pyronix Wireless Deltabell Tamper

    Tampers can be replaced. Potential you’ve inadvertently broken the bell box cover one if you weren’t sure what you were doing they are very sensitive. There’s also a screw one that senses whether it’s being pulled away from the fascia of the building
  15. D

    Pyronix Alarm - Error Message

    You could change just the device with the issue but the advice is to replace all
  16. D

    pyronix alarm - wireless low batt

    Show us a photo of the inputs and we can work out what batteries or alternatively punch in the engineers code, open the sensors up to check what batteries are needed, order them up and do this again to change them when they come You are as well changing them all
  17. D

    Pyronix door sensor

    And what if someone targeting your property waited until you left, disabled your external sirens in broad daylight in a way that appeared they were in fact an alarm company…. Only to come back of an evening to break in? The end user comes home notices a tamper on their panel looks at the...
  18. D

    Pyronix door sensor

    My message above applies. Until you try you won’t know whether the engineer has set it up for solely an engineer reset. If you have an engineer company you could ask them if it goes pear shaped Either way it sounds like you need to remove the sensor so…
  19. D

    Pyronix door sensor

    No the tamper will go off. Stop it with your code and hopefully your engineer has set it up so that your code can reset the tamper also.