  1. mario500

    Unsafe gas valve or me over-worrying?

    Hard to say for sure, but it sounds like the ignition rate isn't correct.
  2. mario500

    Resiting boiler.

    Can be installed anywhere that the manufacturers in structions say - ie min clearance top, bottom, front and sides. So long as there is a route for the flue, pressure relief and condensate pipework, and of course the boiler can be supplied with flow return gas and hot/cold then no probs.
  3. mario500

    Unsafe gas valve or me over-worrying?

    Jesus - why do these nomarks just bolt on a gas valve without setting it up properly???????????????? :evil: AL
  4. mario500

    baxi solo

    Either your flue is getting water ingress or the burner pressure isn't set correctly - allowing condensation to build up. Both of these faults need to be checked out by a GOOD heating engineer. AL
  5. mario500

    Brittony 28SE

    Ok finally got back to this one due to difficulty obtaining parts :cry: I found that the diverter valve was stuck in the DHW mode - so when in CH the flow was just flying around the plate hex. Changed the hydraulic block along with new valve - refilled and at last rads warmed up nicely. Then...
  6. mario500

    Brittony 28SE

    Cheers fella's I did wonder about the middle solenoid - i was wondering if there was a test for them. Although If I pull off the wires to them the boiler either goes to low flame or no flame. I don't know if there if a mid set flame modulation, but would really like to :( Yes fella - the...
  7. mario500

    Brittony 28SE

    Cheers Cso30 Thermistors for these are 25 quid plus vat each. But I did change them both anyway. The pump head is only a year old - in fact I put on for the guy. I will test though when I am there next. The thing that has had me struggling is the temp differance! why does the boiler...
  8. mario500

    Brittony 28SE

    Update Second visit I measured flow and return temps - flow was only 68 degrees even though the leds said it was 80 degrees. The temp differential was between 24 and 18 degrees!! too high I thought. With a 10 k ohm pot connected instead of CH thermistor It was possible to get the...
  9. mario500

    Honeywell CM907 Connections

    It is possible to take stuff back to shops you know! nah nah ne nah nah :wink:
  10. mario500

    Honeywell CM907 Connections

    Why have two programmers? what on earth for? Just my thoughts, but I personally would install a basic room stat with a digital display. I guess the other consideration is which controller is more convienient? the origional programmer or the location of the stat. If say for example the...
  11. mario500

    Oso unvented cylinder problem

    Oso cylinders are quite good. Maybe your Ch system has a problem with corrosion? Do you have to bleed rad on a regular basis? The surge in domestic hot water in unrelated to the radiator problems. Maybe your expansion vessel is undersized or maybe the diapram inside is damaged. The...
  12. mario500

    Honeywell CM907 Connections

    The Honeywell cm907 is a chronotherm programmable stat. I would say that it is a bit overkill for the Y plan system that you have. I personally would install a basic digistat which would measure the air temp very well and would have a digital display. A cm907 is more suited for a combi...
  13. mario500

    Honeywell CM907 Connections

    Don't need the blue so tape it up. Red should be one I think and yellow 3. The wiring diagram with the Honeywell is very good. What system are you putting it on? AL
  14. mario500

    Brittony 28SE

    DHW fine CH Warm rads, but not up to temp. Large house but rads furthest away getting warm (at top). Temp differential on flow and return seem quite high - but couldn't measure properly due to time. Will measure accurately tomorrow. With CH temp selector on full the boiler gets up to...
  15. mario500

    Part for Glowworm 24HXI

    Hi men I am after a part number for the plastic inner flue (inside boiler) for the above. It is the part that the flue spiggot pushes into when installing the flue - the bit that has the rubber seal where the condensate runs into (it connects to the combustion chamber. Ta AL
  16. mario500

    Jaguar Boiler Pump

    I changed one with a Bg standard pump head - with a slight mod on the alignment nib if memoery serves. Trouble is can't remember who makes the pumps for Bg now??? Anyone know?? Al
  17. mario500

    No pressure or DHW on Baxi Instant 105e

    A new diaphram is needed as previous poster says. The symptoms describe confirm that. You should be able to get both parts for less than thirty quid and both are easy to change on that model. - but you may find that your expansion vessel has gone also - to test that you need to undo the cap and...
  18. mario500

    Baxi Combi 80 Eco

    Ah - not timer fault then if you turn ch temp right down to lowest setting and boiler is already hot. Something else is creating a demand - maybe micro switch on divertor gone to closed circuit? maybe divertor stuck in the dhw mode? Al
  19. mario500

    DHW HE or DHW Thermister

    Gasmick - very useful information there - will put it in the grey matter - or maybe write it down lol Al
  20. mario500

    What's wrong with my Vaillant Ecotec Plus boiler?

    Surely this appliance will still be under manufacturers warranty????? Al