  1. G

    Multimeter shows power when circuit breaker off

    I am about to change over an external security light and wanted to be 100% certain the power was off before meddling around. An electric shock whilst up a ladder is not worth thinking about. Anyway, I switched off the circuit breaker and double checked with the NCV setting on my multimeter. Very...
  2. G

    Anti syphon trap

    Hi I have noticed occasional drain smells in the bathroom, that seems to come from the bath plug hole. As there is a shower (and sink), the bath is rarely used, and just by running a little water in the bath, the smells goes away. The bath trap is not very deep so I could change it over for one...
  3. G

    Toilet flapper - universal?

    Hi I have moved to a new house that has a new dual flush Roca toilet. Afer flushing, some water continues to run through from cistern to wc bowl. I realise this is a "flapper" problem and have taken a look but cant see any obvious damage to the large plastic washer. Reading on forums, it...
  4. G

    Equilibrium ball valve

    Hi I had a problem with the ball valve in cold water tank in loft. I replaced it but now get a mild case of water hammer coming from loft area. I am wondering if the old valve was an equilibrium valve, which would explain it, as I just fitted a straight forward cheap one. I still have the...
  5. G

    Minimal voltage in old ring mains

    Hi I am confused! Whilst decorating, I found buried in the wall, two mains size cables (each with red, black and earth cables) that are simply terminated with insulation tape. It looks like they were part of a ring mains and were probably both connected to a mains socket. I tested it...
  6. G

    Timer in lighting circuit

    Hi I want to install a timer to control the lights in our front room in addition to the existing light switch. We have 12 x 50 watt (mains) down-lights so this is too much for any timer that simply fits in place of the existing wall switch, at least more than one I can find! So I thought I...
  7. G

    Extra rads fed down from upstairs

    Hi I thought I should open fresh thread for this question. I had a problem of 3 sepaarate leaks in radiator pipes bedded in a concrete floor. It started after a power flush and although everything has stayed dry for the last 3 or 4 weeks, I have lost confidence in that pipe work so want to...
  8. G

    Draining system

    I need to drain down the system and may have to do this a few times. I was wondering if I could save some time, and also money on inhibitor, if I closed all the radiator valves to reduce the amount of water that drains out. Is this Ok, or will it lead to air lock problems etc? One reason I...
  9. G

    broken connection at toilet push button

    Hi, would be really greatful for some help. On removing the push button for the wc, I must have snapped a tiny bit of plastic of the fitting that clips on to the back of the button. This is a white plastic "box" that is connected by pipe to the flushing valve. So now, the plastic fitting...
  10. G

    Single pipe central heating

    My son has moved house (with his young family) and the central heating is very poor. He had a heating engineer round who was completely stumped but then realised it is what he calls a single pipe system. He has explained that the hot water goes from radiator to radiator in turn, so when it...
  11. G

    Problem with motorised valve??

    Hi, My first posting although I have followed this excellent forum for a long time. I have what I think is called an "open" system (Not a combi boiler). The boiler is old but seems to work fine. The radiators are on, but the only way I can get the radiator in the bathroom on (which is on...