    Distance from Hob

    When installing a hob, its recomended that you keep all sockets etc 300mm each side from it. If the hob was installed at the front of a worktop and the socket was directly behind it but 300mm away would that be ok?
  2. N

    TT Systems

    32A sockets the loop imedance should be less than 1.2 ohms, but if its a TT system how is it gona be below this? Is it ok to just give it an RCD for supplementary protection? Do the figures for max loop in regs not apply to TT systems?
  3. N

    SWA Size

    Cant read it, just thought they was a way of working it out from overall diameter
  4. N

    SWA Size

    I've got 2 SWA cables, one is 20mm in diameter the other is 16mm, what size cables are inside them? They are 3 core
  5. N

    T&E in Conduit

    What u mean by that?
  6. N

    T&E in Conduit

    I want to get 2 2.5mm T&E, 1 1.5mm T&E & 1 6mm T&E cables from one building to another using conduit. What size will i need? Will it be 2 x 20mm or 2 x 25mm? Were in regs do i find this info? It seems just to be for singles, is they an easy way of working out?
  7. N

    RCD Problems

    You might need to get someone to do an insulation resistence test on these circuits to determine if theres a short
  8. N

    RCD Problems

    Have you tried unplugging everything on all circuits that are tripping, then turning the circuits on?
  9. N

    RCD Problems

    Please list circuits on DP side of board, then circuits on RCD side.
  10. N

    RCD Problems

    Is it a split load unit? What 4 circuits can you turn on that dont trip it?
  11. N

    RCD Problems

    When did this start happening? Switch off all circuits, then turn on RCD, test each circuits indivially to see which ones trip it
  12. N

    No earth on Lights

    Been to a house today and found the lights had no earth cable. Most of the lights in the house are metal fittings. The lady dosn't want it rewiring as its just been decorated, so would putting them on an RCD be sufficient? I inspected the fuseboard only to find that they was no main earth...
  13. N

    Earth leakage

    How can i do that? Isn't cpc too close to phase so would pick up that reading?
  14. N

    Earth leakage

    ok cheers
  15. N

    Earth leakage

    How can i find out how much earth leakage there is on a cooker?
  16. N

    Joining SWA and TW&E

    I'm wanting to run a SWA cable to supply an outbuilding. The SWA needs to be 16mm^2 because its a 34M run and I have to take volt drop into equation. Unfortunately the run from the consumer unit to the outside wall is quite a bendy 5M run (up stairs n round corners), so i propse to use TW&E from...
  17. N

    Candle shaped bulbs

    No shades just exposed bulbs, voltage is 239V
  18. N

    Candle shaped bulbs

    I've been told that candle shaped bulbs tend to not last as long as normall shaped, is this true? :roll: Just had a look at some wall lights that have candle shaped tungsten filament bulbs that keep popping. I've checked fitting and everything seems to be in order, any suggestions what it...
  19. N

    TW&E Clips

    Been using TW&E clips from screwfix for some time now, but they never seem to stay in thermolite blocks. Does any1 else have this problem? Where can i get some decent ones as most places sell the same tower brand
  20. N

    SWA Diameters

    So if XLPE was drawing its max rated current it would operate at 90 degrees?