    Knocking Radiators

    My rads keep making a knocking sound, I assume when the TRV's are shutting down. There's an automatic bypass valve fitted and the system is all fernoxed. Is there any way of getting rid of the noise?
  2. A

    Automatic Bypass Valve

    I'm not trying to set it, I'm trying to understand what its been set at and why? Anybody know how they should work?
  3. A

    Automatic Bypass Valve

    The Pegler Automatic Bypass Valve has a dial going from 0 (fully off) to 5 (fully on). What does it mean to have it set to 0 and then set it to 5, when it's connected to the usual flow and return pipes of a Combi boiler.
  4. A

    Whistling rads?

    I think the ABV is on about 4.5, is that too high/low for 18 rads? The boiler is a BAXI 133HE Plus condensing combi, the max heat out put is about 100,000BTU although my rads add up to around 60,000BTU. I think the whistling trv's are on the flow and the sound does seem to stop if you...
  5. A

    Whistling rads?

    I've just had my central heating system balanced - auto-bypass set and lock shields set - but some of the rads are now whistling. Is the problem that the auto-bypass hasn't been properly set or something else?
  6. A

    How to get Freeview?

    I want to get Freeview but they don't cover my area. The Freeview bloke said that it wasn't a problem because I can get it on cable or dish, anyone know who supplies it and which is better?
  7. A

    How to set automatic bypass valve?

    How do you adjust and set-up an automatic bypass valve the first time? One of my TRV's whistles sometimes I think the ABV needs to be turned up but I'm not sure.
  8. A

    Wireless household alarms?

    Can anyone recommend a good wireless alarm system, with about 8-10 PIRs. I saw one by a company called Friedland (Model SA5), although it came with only a couple of PIRs they say that you can add as many as you like, is it any good? Anything to watch out for with wireless alarm systems?
  9. A

    Why two pumps in combi?

    The Baxi Condensing Combi 133 HE Plus boiler comes with a maximum heat output factory set at 80,000 BTU, you can increase this to 100,000BTU by fitting an extra Grundfoss 15/50 or 15/60 pump. Does anyone have any experience of having two pumps in a boiler? I've not come across this before...
  10. A

    To Fernox or not?

    I'm having a new combi and new pipework put in, the system needs to be cleansed and then protected. Planning to use Fernox for both but not sure which ones, there are 18 radiators in all. For cleaning - the DS-40 System Cleanser or the Superconcentrate Central Heating Restorer, and how...
  11. A

    Interior painting

    Does that mean I might be better off using a "Trade" paint instead of the normal retail stuff because its thinner? So instead of two coats of the normal stuff maybe say three coats of the Trade paint.
  12. A

    Interior painting

    Thanks, I was going to leave it for about four days before trying painting, is that enough or should I give it some more time? By the way, whats the difference between a mist coat of emulsion and the commercial stuff like PVA and Dulux Plaster sealer.
  13. A

    Interior painting

    The walls and ceilings have been freshly plastered with Thistle Multi-finish. Before painting them is it a good idea put on some PVA to seal the surface? If so, how long does the PVA have to be left on before painting and how much do you need to dilute it.
  14. A

    Exterior Painting

    I've noticed a few (hairline) cracks in the cement render, should I fill these in now or is it best to leave it till next summer when I come to paint it and fill it in then? If the latter will I need to use some fungicide?
  15. A

    Colouring Concrete

    Is there a colouring product that I can add to concrete to colour it? I was looking for something that'll give me a burgundy type end effect and comes in a large container because I might need lots.
  16. A

    Exterior Painting

    I've cement rendered the outside of my house but the weather isn't too good now so I'm thinking of leaving the painting till next summer. Can I leave it exposed as it is or do I need to take some precautions?
  17. A

    Identify Pilkington K Glass

    I've just have some double glazing fitted, the company who did it said that it was all Pilkington K glass. But I can't find any markings on the glass to say that its K glass. Does anyone know what markings I should be looking for or how I can tell?
  18. A

    Smoothing external render?

    The render is flat in places, just that the surfaces aren't the same level in all places, but when you rub on it with your hands it doesn't feel smooth. I'm told thats how cement render feels and painting it will give a smooth finish, but I would have thought that if the surface is rough to...
  19. A

    Smoothing external render?

    I've rendered the external walls with a (2 coat) sand-cement mix. I'd like to paint it to get a smooth finish. The walls are a bit rough and not completely flat in some places. Do I need to apply a top coat (of what?) to get it flat and smooth it before painting, or would it be better to...
  20. A

    Combi water softener?

    I'm fitting a new Baxi HE Plus condensing combi boiler and was wondering if its worth fitting a water softener. The Tapworks AD10 looks good but a friend mentioned that putting one in might invalidate my boiler guarantee, and the boiler might only last half as long. Is that true? I looked...