  1. D

    Pump setting for microbore system

    Moved into our current house nearly two years ago. It's a mid-80 link-detached with a WB CDi 37 Combi boiler. The boiler is in the first floor airing cupboard. It appears to be a microbore system as there are 10mm surface mounted pipes coming down the wall from the first floor. They all convert...
  2. D

    vaillant ecotec plus 837 pump radiator problem.

    Was it working OK previously and this is a new problem?
  3. D

    Replacing T6360B thermostat for a DT90E thermostat

    You're quite correct. I was thinking the red was also connected to 1; which leaves two spare wires - the red (3) and black (not connected). I suspect there are two separate cables: red and black (old style); and (new style) brown, blue, green/yellow and one with white sleeve conneected to 3. If...
  4. D

    Replacing T6360B thermostat for a DT90E thermostat

    Aren't we jumping the gun a bit? I would need to know why there are three extra wires first, before pronouncing exactly what needs to be done - apart from making safe, in a terminal block, the earth wire and the neutral in T2.
  5. D

    Pump runs continuously in new installation

    Despite being called a "heat only" boiler, which usually means it's open-vent with an external pump, the Keston Heat2 is actually a "system" boiler with a built-in pump. Is this the Yonos Pico pump you mention? Or is that a second, external, pump fitted because you have a very large installation...
  6. D

    Managing a CH system fitted with an automatic bypass valve.

    A TRV must not be installed on the radiator in the room where the room stat is located.
  7. D

    Grundfos pumps

    You are probably correct. Unfortunately, the OP has involved us at the end of the system design stage so there are many questions left unanswered.
  8. D

    Grundfos pumps

    There's an inconsistency between the statements above as a "sealed system" normally means a system boiler boiler with integrated pump; while a "heat only boiler" is usually open vented with a external pump. We need to know exactly which boiler is being fitted - make and exact model. If the old...
  9. D

    Grundfos pumps

    Both pumps have been discontinued by Grundfos, so what you have found are end-of-line stock. With 35 radiators, you have a very large system. Has anyone calculated the system index (max head and flow rate), so you know what size pump to buy?
  10. D

    Atag boiler short cycling

    Very likely the unintended, but expected, effect of Brexit.
  11. D

    WB CDi37 Classic permanently on minimum output

    Spoke to the heating engineer this morning. He couldn't explain what was going on, but wondered if the condensate drain pipe had got blocked again - it is only 22mm plastic all the way from boiler to drain, including going down the side of the house. He couldn't come until Wednesday or Thursday...
  12. D

    WB CDi37 Classic permanently on minimum output

    CH Temperature Control When you turn past 6 up to max you can feel a switch operate. What, exactly, does the switch do? What happens when you turn the control back, i.e turn the switch off?
  13. D

    Atag boiler short cycling

    I can't work out which way is up on this pic. It looks as if the pump is lying on the floor pointing upwards which, if it is, is the worst way to install a pump as it will wear out very quickly due to lack of lubrication. The pump shaft mut always be horizontal. If the pump is installed as at...
  14. D

    WB CDi37 Classic permanently on minimum output

    Clambering on the sloping garage roof on a cold Sunday afternoon to pur water down the flue is not high on my to-do list. However, I have found this in the Installation Manual: To Clean the Condensate Trap 5.1 Pull condensate pipe out of the adaptor. 5.2 Remove trap from boiler. Clean trap and...
  15. D

    WB CDi37 Classic permanently on minimum output

    Reset all parameters this morning (8.E = 0). The boiler resarted and went into the venting cycle for several minutes. The temperature rose and, at one point the boiler seemed to go into the syphon fill program as -//- appeared, but only for a few seconds. The flow temperature is now rising to...
  16. D

    WB CDi37 Classic permanently on minimum output

    Good point. The display only shows the flow temperature. When the syphon is filling it should be showing -//- alternating with the temperature, which isn't happening. This suggests a fault in the PCB. Maybe resetting all parameters would help?
  17. D

    WB CDi37 Classic permanently on minimum output

    The boiler is about 12 years old and was working correctly until a few days ago when it decided to go on strike - no heating or hot water. The pressure had gone down to zero. I tried to repressurize it but had diffuculty fitting the key - so did my son, who pointed out that there was some water...
  18. D

    Boiler power!

    That's an eight degree differential. The boiler is designed to work with a 20 degree differential. One of the reasons for this is the very high pressure loss across the heat exchanger when the flow rate is high, e.g with a small differential. Increasing the setting of the bypass by turning screw...
  19. D

    Grundfos Alpha2 15 60 130- Pump speed and noise issue

    I hadn't noticed the discrepancy. You are correct in saying that the LS valve has to be closed to reduce the flow and increase the differential, i.e the difference between flow and return temperatures; and vice versa. The language is confusing - temperatures can be high or low; differentials...
  20. D

    New boiler not big enough

    So the TRVs could all be stuck closed or partly open. Remove all TRV heads and check that the pin in the metal body can be pressed down without sticking and returns when released. If the pins all work correctly, but radiator temperatures are different, the system needs to be balanced.