  1. N

    3 way switching

    For 3 way switching, If the permanent feed is at switch 1 can the switched live be at switch 3 ? :?
  2. N

    Oil & electric Heating wiring

    Excellent. Thanks for the replies :wink: Is that definately the part no. for the diverter valve. Cant seem to find it. Have you got a link ? Cheers
  3. N

    Oil & electric Heating wiring

    Ill see if I can find a link The plumber was on about using some sort of relay in the circuit but I didnt quite know where. I didnt dismiss this until I got home & had a think. Cheers.
  4. N

    Oil & electric Heating wiring

    Ive got a situation where I wired a 12KW boiler into a new build & now an oil boiler has got to be installed. The programmer which is a Horstmann H37XL is controlling the heating at the moment. The customer wants the oil boiler to take over from the 12KW boiler but still have it as a backup...
  5. N

    Would length of circuit make RCBO trip

    it was a discussion goldberg. I was asking about rcbos not how to do my job. Anyway engineers for this particular maintenance company decide what cable and circuit breakers to use and i do the connections and testing.
  6. N

    Would length of circuit make RCBO trip

    Yes I did & the results were all >299. Only did it on 500V, maybe I should have done it on 1KV
  7. N

    Would length of circuit make RCBO trip

    Doing some electrical connections on the motorway for some CCTV & one of the connections to the camera is approx 500 metres from the supply. When I put the switch up on the RCBO it wouldnt reset. Disconnected all the load on the cable & it still wouldnt reset. Ive walked the length of the...
  8. N

    downlighters Shower - fitted close to the joist!

    They were CFL type, 11w
  9. N

    CU voltages querey

    yes yes yes yes I didnt expect to get 113V. If this is normal then fair enough.
  10. N

    downlighters Shower - fitted close to the joist!

    I fitted some low energy shower downlights last week & customer complaing the light is not bright enough & its like a tunnel of light that comes out of the fitting. They are not the JCC ones though.
  11. N

    CU voltages querey

    supply L & N voltages 246V with main sw off Ill be looking tomorrow because I couldnt get access but there was someone on site that said the supply had its own meter & cutout & was fed through a 100A type C Circuit breaker. The run from the meter to the office is about 10Metres in 25mm SWA &...
  12. N

    CU voltages querey

    Testing a split load CU today that another Electrician had fitted. It was in a very small office. There is one ring with 6 sockets & 2 lighting circuits (1 for the kitchen & toilet & 1 for the main room) All CU switches were off & the circuits were connected in the CU, but when I measured...
  13. N

    Cooker circuit without RCD question

    We know that socket outlets need 30ma protection but what slightly concerns me is the NIC tech helpline says one thing, (but they are thinking in the real world) & other electricians say another. At the end of the day I'm getting paid anyway but I could have been doing something else. It...
  14. N

    Cooker circuit without RCD question

    I agree Pensdown but I could have argued the toss all day with the bloke & he started to do my head in. I cant believe the NIC will be taking another £450 or so, out my bank this month to stay registered with them. I cant re-type the whole conversation with the bloke but it was like talking to a...
  15. N

    Cooker circuit without RCD question

    BAS - Ive never met the Electrician that did the PIR's. The landlord gave me a list of things that electrician had found & it wasnt a PIR list. I've not done any certs as the landlord said the other electrician will check I have done whats on the list. Spoke to the NIC today (when I could...
  16. N

    Cooker circuit without RCD question

    OK no probs, just wanted an opinion. Plenty of room for everyone :wink:
  17. N

    Cooker circuit without RCD question

    Well its just not chipping it out is it. When you got x2 10mm cables coming in & out of the backbox from each side in plaster it isnt easy to make nice job of it.
  18. N

    Cooker circuit without RCD question

    Have you got a link to it, I cant find it. :wink:
  19. N

    Cooker circuit without RCD question

    No I cant BAS, tried it. It wouldnt be easy to split the tails either cause the meter box is about 3 metres away from the cu on the outside wall but I suppose I could put them on the surface in trunking.
  20. N

    Cooker circuit without RCD question

    Just started doing some maintenance for a landlord & the previous electrician had done PIR's in all the properties. Been running through the list of jobs & one of them is "no rcd on cooker circuit" (it has a socket) Now I could replace the double cooker switch with one without a socket but it...