  1. L

    CU replacement advice needed

    A board change and all the testing in 3 hrs :lol:
  2. L

    shower unit leaking

    As Andy said above, it will be the PRD usually caused by shower head holes blocked / partially blocked by limescale.
  3. L

    New fuse always blows when I turn on brand new oven.

    Which fuse blows, the one in the plug or the one in the consumer unit?
  4. L

    Do I need a new CU?

    Will a 10mm cable be OK for a 10.5kW shower if the cable is to be installed in conduit?
  5. L

    Bathroom Lights

    The insulation is removed to allow adequate airflow around the light fittings to prevent them over heating, but as you say you are losing heat around them and more importantly allowing moist air from your bathroom to enter the loft space. Even LED lamps run hot so will require a good sized space...
  6. L

    New wall light is dim

    A picture of the wiring would help, but it sounds like they are connected in series rather than parallel.
  7. L

    Replace Gainsborough10.5 deluxe shower

    Any make will be OK to replace it with. The biggest problem will be getting one where the water and wiring entries match up with your old unit. Tiles should go behind the shower not be cut around it.
  8. L

    building regulations

    I don't think there is anything in the building regs but there is something in BS 7671 which says about gangways around electrical control gear. I don't have my copy with me at the moment so can't give you references but if you post on the electrical forum I am sure someone on there will tell...
  9. L

    Add a new double socket in garage

    Forget the connector and just connect into the back of one of the existing sockets.
  10. L

    Electric cooker and gas hob from single flex outlet?

    You could try one of these. http://www.alertelectrical.com/prod/1022/click-45a-easyfit-dual-appliance-outlet-plate
  11. L

    RCD puzzle

    ivixor, where abouts are you in Cambridgeshire? If you are near Peterborough I may be able to help.
  12. L

    RCD Protection for Outside Socket

    It is also worth having it switched from inside to stop other people using your electricity if the socket is accessible by neighbours etc.
  13. L

    MEM consumer unit

    What earthing system does your house have?.
  14. L

    Electric shower to replace dads old one

    You will need to consider RCD protection for the new shower.
  15. L

    veritas r8

    You say you have put all the cables into connector blocks then ran singles to the board, do the tampers not need to be wired in series rather than parallel?
  16. L

    Tracking down non standard size T5 fluorescent lamp, please!

    I had the same problem a couple of years ago, it was easier and not that expensive to swap out the complete fitting for a standard sized one.
  17. L

    Downlights led

    What do the manufacturers instructions say?
  18. L

    Lighting Circuit Help

    Red wire on left in second picture had indent in it which looks like you nipped it with the face plate screw.
  19. L

    Replacing a shower

    If the cable is only 10mm across then it sounds like 2.5mm2 cable which is no where near big enough for your new shower. You need an electrician to upgrade your feed to the shower and provide you with RCD protection.
  20. L

    Replacing a shower

    When you say the cable is 10mm is that the measurement across the cable or is that what is written on the grey outer sheath?