  1. C

    registering a new boiler

    Apart from your registration, be it the company you work for, or your own personal registration, you should be covered by the companys Public Liability Insurance. If you undertake "private" work, you will not be covered !!!!!!,, thats unless you have, your own cover ! If you get it wrong...
  2. C

    Vaillant 824 combi hot water

    PCB U/S,,, if you have exchanged the D/ Valve Dave .
  3. C

    biasi 24s

    If the fan don't run, theres a reason why !!!!!!!!! :?
  4. C

    24cdi flame failure - maybe

    Ditto Chris, its only my experience, but i have had similar problems in the past, with Worcesters, esp CDI range. The wiring looms , especially were they join the connectors , suffer from dry joints. I know its a pain, test every wire back, for continuity. ( not teaching you to suck eggs ...
  5. C

    noisy motorised valve

    Sounds like the motor inside is about to fail, you can change some types. Dave.
  6. C

    Problem recharging pressure on Worcester 28CDI RSF

    Sorry just read your post a bit more , my fault , you say water is present , what under pressure, or drips !
  7. C

    Problem recharging pressure on Worcester 28CDI RSF

    Can you here water entering the boiler!! If so , as already said its a blocked pressure gauge , or the actual needle is stuck , try flicking the gauge with your finger. Dave.
  8. C

    Problem recharging pressure on Worcester 28CDI RSF

    Could be be one the suggestions pointed out above ,,, although this boiler and others, in the range, with the same type of integral filling loop, suffer from a common fault ,, IE is the grey plastic knob actually opening the valve, or just riding over the worn spindle,, check this out . Good...
  9. C

    Loud Bang on fire up

    Ideal what ? model :wink:
  10. C

    low boiler pressure

    We never "did" find out what boiler he/she was driving :lol:
  11. C

    Turbomax 824e / VUW 242/5

    Cheers Chris, about 15/20 seconds as it says in the book "ha" and yes its getting hot , the H/W and C/H too, although its a small system ,, 4 rads, and no i didn't install it either :lol: Burner pressure stays static, but doesn't modulate up on H/W demand :? Must admit , didn't check S...
  12. C

    Turbomax 824e / VUW 242/5

    Good evening chaps, Any info/ help would be really appreciated. Initial problem, was no / or intermittent H/W, so first things first, rectification problem,, sorted that one out. Still boiler fires for a short while then goes out ,,, fan ok, APS, ok, gas valve ok, pump and impeller...
  13. C

    worcester combi

    Worcester,, have made, and continue to make a whole range of boilers, so,,,,,,, if you would like some form of help, a particular model wouldn't go a mis. :? Dave.
  14. C

    combi boiler

    Just the 1 hot tap, or all the hot taps ??? Need more info. Dave.
  15. C

    unable to repressurise Worcester 28CDi after drain down

    Just to add, totally agree with croydoncorgi, if you do get round to removing the D / Valve at the back is or should be a small inlet water filter. Although it could be blocked but i very much doubt it. Reason been, water authority down here have been changing water meters and its caused...
  16. C

    unable to repressurise Worcester 28CDi after drain down

    As previous posters have said, there is not much to the filling loop itself. As you look at the filling loop, the right hand side joins directly to the diverter valve, via a O ring seal. The diverter valve could be blocked, the other end connects , if i remember to the flow side of the...
  17. C

    Vaillant 242E blowing PCB Fuse

    Ditto,, as Tony said failed pump, had exact same prob Friday, although AAV was leaking bad ,,, and didnt help. Dave.
  18. C

    Worcester 28 cdi Combi no HW when CH is on.....

    Worcesters, are generally very reliable boilers, especially the CDI range. Yes if you have a rapid flash , this would indicate a possible fault with either the flue, and or , the PCB, although there is more than just the flue. It could be a fault with the APS, or the tubes connected to the...
  19. C

    hot water not hot enough

    Its a new boiler, as said , gas rate, then go from there. Dave.
  20. C

    Vaillant Turbomax 828E No Central Heating Demand!

    This is purely based on my experience, Turbo Max, and of late, the Echo Max have a nasty habit of failing in either C/H mode or H/W mode. Genrally, if you have absolute nothing, then 90% f the time, yes the boards dead. In answer to you question, yes i would say the board is at fault, but...