  1. gasman26

    BAXI COMBI 105e..... HOT WATER BUT NOT TO RADS

    Possible blocked main heat exchanger.....
  2. gasman26

    micron 50ff fan

    Richest man in the graveyard :D
  3. gasman26

    it sounds like, the gas valve needs setting up correctly by an RGI.

    it sounds like, the gas valve needs setting up correctly by an RGI.
  4. gasman26

    does my system need to be drained to fit trvs?

    8 hours for 4 TRV`s :shock:
  5. gasman26

    Looking for reliable 24kw boiler for open vent system.

    Have fitted in excess of 100 of the heat only without a single fault (tempting fate now :shock: ) http://www.avantarange.com/heating_boilers.html As advised use the whole house calculator first to ascertain what size you require. 5 year parts and labour warantee (dependant upon installer)
  6. Untitled

    Untitled

  7. new

    new

  8. gasman26

    Much water from Condensing Pipe (Worcester Greenstar Jnr 28)

    Or the pressure relief valve is letting by...... tie a plastic bag around the discharge pipe to check for this.
  9. gasman26

    BOILER SWITCHING TO RESET

    Symptom of a faulty P.C.B, very common fault on the microns, we must have changed 30+ There have been 7 modifications/updates to the MicronFF P.C.B since this piece of junk was released. The latest modified board seems to have solved the intermittent lockout problem.
  10. gasman26

    is nvq3 worth anything???

    City & Guilds Level 3 NVQ in Domestic Natural Gas Installation and Maintenance 100/1919/4 This would be the ideal route if you were wishing to enter the gas industry.
  11. gasman26

    Changing old central heating programmer

    You could even replace it with an up to date sangamo 7 day electronic control http://www.sangamo.co.uk/web/site/Products/RPTS/e850_series_standard.asp Great timeclocks, will probably out last the boiler.... You just need to determine whether you have a 3 or 4 pin currently, then its just...
  12. gasman26

    Honeywell

    You can remove the actuator from the valve & check that it drives for at least 10 seconds, if so the valve itself is jammed, have had a few of these.... Have a look under fault codes http://content.honeywell.com/UK/homes/Technical/Yplan%20Installation%20Guide.PDF
  13. gasman26

    Honeywell

    Honeywell smartfit installation... F4 fault is 3 port valve jammed, either seized or the actuator isnt travelling fully.
  14. gasman26

    Landlords Gas Safety Checks

    Ignoring the CORGI laws, where does it say that in the GSUR which is the real law of the country? Tony Ingenious.. lets all ignore corgis advice Why not go the full hog, cancel your corgi registration & let your a.c.s expire? :D
  15. gasman26

    Landlords Gas Safety Checks

    I actually phoned CORGI a while back for clarification on this. I was advised that Landlord safety cert`s must be carried out both annually & every time there is a change of tenant. The reasoning behind this was to cover the possibility of the ex-tenant taking appliances with them e.g cookers...
  16. gasman26

    Converting y plan to s plan troubles

    Pump L - 9 N - 2 E - 3 Boiler connections SWL - 10 L - 1 E - 3 N - 2 Pump L - 9 N - 2 E - 3
  17. gasman26

    Gas Pipe Routes from Meter

    Try this www.omegaflex.co.uk
  18. gasman26

    New poster

    By the way the answer your looking for is a maximum volume of 0.035m cubed.......
  19. gasman26

    New poster

    Hi Gforcejames, recognise that corgi number a fellow Connaught gasfore employee... James Richards by any chance?? Use to work out of Wrotham office, now working out of Bromsgrove... Glad to hear that mr Price has moved onto pastures new....!!