Search results

  1. gasman26

    boiler recommendation

    Try looking at the Broag Remaha Avanta 39c condensing combi 16 ltr/minute.... In my opinion far superior to your vaillants & worcesters. We work as agents for Broag and they only have a 2% failure rate on warranty defects (2yr parts & labour) The output modulates down from 6-39kw, dependant...
  2. gasman26

    JOB INTERVIEW QUESTION FOR BOILER COMPANY

    :oops: I take the oL comment back, don`t know where that came from :D
  3. gasman26

    JOB INTERVIEW QUESTION FOR BOILER COMPANY

    Low water content on gravity - noooooooooo Check for suitably rated fuse according to boiler/system Earth Continuity - Under 1 Ohm, between appliance earth & at various points around the case Short Circut Check - Between L&N Zero - ohms or oL indicates a short circuit (fuse removed...
  4. gasman26

    Ravenheat boilers - what do people think?

    Tommygee... yes thats inclusive of V.A.T also... contact me via my email address listed on this site by clicking my name if interested...
  5. gasman26

    Ravenheat boilers - what do people think?

    Agreed Broag remeha avanta 28 is an excellent boiler (definate contender for vaillant g4u :D) Although I may be biased as we are agents for Broag.. Can provide including flue kit & free delivery £670.....
  6. gasman26

    vaillant 242E, 282E

    Switch the boiler to hot water only & just check after turning off the hot water tap that the burner is actually going out.. The water valve at the bottom of the boiler has a diaphragm with a pin that activates a microswitch on the servo & tells the boiler to ignite... these scale up & seize...
  7. gasman26

    Removing open flued appliance.....

    I believe its right what they say, especially in this case.... plumbers are failed gas fitters!!!!
  8. gasman26

    New CH system - knocking rads

    you`re right gas4you straight trv4`s are not reversible flow! get your plumber to swap the trv`s with the lockshields, job done!
  9. gasman26

    Removing open flued appliance.....

    Considering i went to the british gas school of training in westminster, worked on the tools for 10 yrs, attend up to 10 training courses a year, work as an agent for:keston, broag & ideal, am qualified in N.G, LPG, OIL domestically, commercially & industrially not to mention part L & P..... how...
  10. gasman26

    Removing open flued appliance.....

    If you would have read the question correctly i was just asking for clarification...... :twisted: :evil: :twisted:
  11. gasman26

    Removing open flued appliance.....

    Hi i am changing an open flued appliance for a f/f next week..... Could somebody just clarify for me the correct procedure for decomissioning a redundant o/f discharging into a chimney stack??? I have just filled with rockwool and covered with aluminium plate in the past...
  12. gasman26

    New CH system - knocking rads

    sounds like the trv`s have been fitted back to front, either swap the offending items end for end or....... suggest to your plumber that he replaces valves for 4-way reversable flow trv`s (drayton trv 4`s always a favourite)
  13. gasman26

    Puma Potterton 80 low pressure

    more than likely the low pressure switch is blocked, bridge the switch out, removing one of the wires does the trick. drain down boiler, remove & clean L.P.S, replace pressure gauge at the same time.....
  14. gasman26

    Glowworm swiftflow 100 No heat/HW

    if the boiler fired when you manualy made the a.p.s switch this indicates the p.c.b is o.k It sounds to me as if the fan is running slow (replace fan assembly) also check for blockage in the tubes from fan to a.p.s
  15. gasman26

    Worcester 24CDi gaining pressure after new diverter valve

    posted by ollski : A faulty diverter would bring the pressure up a great deal quicker than that, as already said the problem is a dhw hx. Who said anything about a faulty diverter? which incidently would not bring the pressure up........
  16. gasman26

    Worcester 24CDi gaining pressure after new diverter valve

    apologies.... mis-read the posting stating over the period of time... in that case im inclined to agree with your diagnosis of a split dhw heat exchanger....
  17. gasman26

    Worcester 24CDi gaining pressure after new diverter valve

    It`s possible that the diaphragm in the expansion vessel is split.... Remove the cap from the valve & check the pressure, should be roughly 0.5 bar, if you get water released from the valve as opposed to air this will confirm deteration of the internal rubber diaphragm.