Search results

  1. E

    blackberry apps

    any gooduns that cover volt drop calculations and the such like?
  2. E

    Breaking into a ring main for an fcu and continuing

    lamens terms.. change the socket in the out building to a 13a fused spur, on the outgoing/load side of the fused spur connect your (if required) your sockets. now, wire a 3a fused spur from the last socket and on the outgoing/load side wire your lights. this way your sockets are fused to...
  3. E

    wiring an A42A Smeg Cooker

    oops...yup, tiz early! :lol:
  4. E

    Cable size

    oppoligies if im wrong, but i think the OP was talking about the tank stat. if so, and assuming the heating system is fused to a 3a, a 0.75mm would suffice
  5. E

    wiring an A42A Smeg Cooker

    1. if its the rcd only, potentially, the neutral has been put in the wrong neutral bar. 2. probable an element fault. 3. 5kw / 230 = 22amps mcb rated corect?
  6. E

    Itermittant connection

    is it a dusk till dawn only or does it have a pir too?
  7. E

    hypethetical question...

    i did the same when i was an apprentice, did the wiring in the boat yard and the last few bits whilst on the canal in central brum. some p*ssed up blokes let the bloody thing go... yup, that was slightly embarrasing! :oops:
  8. E

    hypethetical question...

    to be fair it wasnt really about a point just if you were allowed. i now work for a wholesaler so its not really an issue anymore! :lol:
  9. E

    hypethetical question...

    oh absoulutley, did it for a few years myself but always used t&e from the board to the s-f-s on a new circuit.
  10. E

    hypethetical question...

    im deffo with you both but it sort of goes against everything i was ever taught, like it seems like it should be wrong but i cant think of a good reason why it is, if you get my meaning..
  11. E

    hypethetical question...

    ...and it is one.....any reason why you couldnt wire a whole house in flex?
  12. E

    Cable size

    and preferably heat reistant flex :wink:
  13. E

    stairway photocell advice?

    theres always the option of replacing the fittings with ones that have an in-built pir.
  14. E

    Taking bets . . UPDATE

    fecked ballast.
  15. E

    Advice on safety of existing garage wiring

    volt drop = 18mv/a/m (based on 2c swa pvc) multiply by actual load in amperes (running load) multiply by length in meters divide by 1000 if the installation is pre 17th you will be allowed 4% of 230 which equates to a max of 9.2v drop. this will work out whether or not the cable is...
  16. E

    Floodlight

    i had a bath earlier. :lol:
  17. E

    adding a 3 way switch

  18. E

    Bodge the Sparky

    most wholesalers will stock them mate.
  19. E

    Advice on safety of existing garage wiring

    at one point, a garage/outhouse/building which was more than a certain distance from the house (cant remember how far) had a seperate stake. the incoming cable was earthed at the house, and not connected in the outhouse. a seperate stake was used for the outhouse supply. as i can recall, it...
  20. E

    Bodge the Sparky

    looks like an ashley JB701/TB to me :D