  1. J

    Tiles ride up at GRP valley...

    Hello, Where the roofs of my existing house and extension meet at the GRP valley tray, the tiles on the existing roof seem to kick up a bit at the end so you can see a slight wavey effect when you view it from further back. Not nice and straight. This seems to boil down to the rafters on the...
  2. J

    New Ensuite Issues - Advice Needed

    100% I go with the micromanagement option to the max, but will start doing more myself in future. I absolutely dread to think how it will be in 10 or 20 years when all the old timers are gone.
  3. J

    New Ensuite Issues - Advice Needed

    Thanks for this. Yes, there is a temptation just to go back to that original plan. I think there is sufficient depth in the room, just, to basically lose the question mark, come further forward off the wall, and get a proper right angle. Then go through the wall in more of a straight line using...
  4. J

    New Ensuite Issues - Advice Needed

    Thanks for this, all makes sense. I did question the fall from the very start but he kept saying that he has done it to the standard height through the wall and has been adamant that this isn't the problem. There is a fall between the back of the toilet and where the waste pipe enters the wall...
  5. J

    New Ensuite Issues - Advice Needed

    Hi mate, Thanks for this. I actually posted before and after your post - does this additional information change anything for you? By the sounds of it, I'll need to get my builder on the case. Remove the whole soil pipe and connectors outside, remove the loo, remove the flexi pipe. Adjust...
  6. J

    New Ensuite Issues - Advice Needed

    Thanks for the replies, it has really helped... this has been doing my head in for a long while and it looks as though the loo can be ruled out.
  7. J

    New Ensuite Issues - Advice Needed

    I've just noticed this, which probably explains his use of flexi pipe through the wall. The end of the connector is at a slight angle as it approaches the wall... This might be addressed by turning the toilet slightly so that the right hand side will be a little bit more off the back wall. This...
  8. J

    New Ensuite Issues - Advice Needed

    I was thinking to replace the flexi pipe with solid. The second plumber who has looked at it told me that flexi pipe isn't supposed to be used through a wall. I assume the original plumber used it because he was struggling to make the toilet waste pipe connector line up with where the outside...
  9. J

    New Ensuite Issues - Advice Needed

    Hello, I had a new ensuite installed in a bedroom approaching two years ago. Just a toilet and sink. I paid a plumber to do the whole job. Toilet and sink wastes go through the outside cavity wall and into the soil pipe serving the adjoining bathroom (old cast iron soil pipe was replaced at the...
  10. J

    Roof truss lintel support

    Righto, thanks!
  11. J

    Roof truss lintel support

    BC will probably want to see an engineer's report. If I do need such an opinion what kind of person am I looking for, preferably not too expensive and willing to just have a look and do quick letter or email?
  12. J

    Roof truss lintel support

    The roof designer did know there is a door. The same one on site is shown on the plan of my extension which they used to design the roof. What sort of engineer do i need to engage to have a look at this and advise if it is safe or not? Likely cost?
  13. J

    Cavity wall insulation - wall plate

    So will the air flow in your case be over the ply boards you've put in? Presumably can't get under them if the roof insulation is touching the ply.
  14. J

    Roof truss lintel support

    No I was not expecting them to design my extension. That was done by the technician who prepared the plans and who called for a trussed roof structure. He didn't design the roof; he, along with several builders I spoke to, said the roofing company would design it and they would follow...
  15. J

    Roof truss lintel support

    Hello, Just interested to hear any thoughts on this. The roof truss company "helpfully" designed a roof where the main girder truss goes over a doorway and sits on the wall plate of the internal wall, below which is a timber lintel. This didn't become apparent until we started putting the roof...
  16. J

    Cavity wall insulation - wall plate

    Can your ply idea be done from the inside or do we need to go over the rafters near the eaves like the cheap nasty trays?
  17. J

    Cavity wall insulation - wall plate

    But what I mean is, the roll tray stuff is not even 1mm thick. So the idea that it will hold the insulation down over the wall plate and maintain a gap to the felt above seems fanciful. There is no rigidity. Interesting that the roofers merchant asked "what do you want that stuff for, nobody...
  18. J

    Cavity wall insulation - wall plate

    Thanks. Builder has returned with the plastic roll tray stuff and it is a joke. Extremely flimsy. So the rood insulation is just going to push it up to the felt and probably close all the gaps.
  19. J

    Cavity wall insulation - wall plate

    So what is the minimum air gap required over the wall plate between soffit vents and loft space? I will get the builder to put these ventilation trays in and we will just have to put as much insulation over the wall plate as will fit in the small space available. However, we do need an air gap...
  20. J

    Cavity wall insulation - wall plate

    How does that maintain an air gap down to the eaves? Unless that's a different type of roof.