  1. J

    Atag boiler short cycling

    Hi all, hoping someone can help me! I've got an Atag IR24 system (heat only) boiler installed a couple of years ago and I'm having a problem with it short cycling. I'll try to describe my heating system as best as possible: it comprises of 13 radiators of various sizes most of which have trvs...
  2. J

    New Bosch dishwasher full of condensation after cycle

    The dishes are usually dry after the cycle unless they’re plastic, and the new dishwasher actually has more insulation than the old one, and is the exact same size
  3. J

    New Bosch dishwasher full of condensation after cycle

    Hi I’ve just replaced my old Bosch dishwasher with a new Bosch (SMV46GX00G). It washes very well and dries the dishes reasonably well, however the inside walls of the machine are always covered in condensation after the cycle, as the photos show. I’ve been using the auto 45-65°C cycle, and...
  4. J

    Replacing rotten solid wood bathroom floor

    Yes concrete underneath then the insulation boards on top with a damp proof membrane I think and then the chipboard just floating on it
  5. J

    Replacing rotten solid wood bathroom floor

    I’ve cut out the rotten chipboard, but it was just laid on insulation board, no joists or anything! Surely that can’t be right?
  6. J

    Replacing rotten solid wood bathroom floor

    Definitely chipboard, looks like planks of timber due to the solid wood floor that was laid on it. The new solid wood flooring will run in the opposite direction to the existing one (along the length or the room instead of the width) , so screws at the edges won’t work unfortunately. So would...
  7. J

    Replacing rotten solid wood bathroom floor

    These are pictures of the chipboard which is rotten and the existing floor.
  8. J

    Replacing rotten solid wood bathroom floor

    Hi I’m replacing my floor in my downstairs toilet as the existing solid wood flooring was bowed and ruined due to a water leak some time ago. I’ve pulled up the existing solid wood boards and the chip board subfloor underneath is covered in mould, although it is dry now. My plan is to cut out...
  9. J

    How to terminate a cable out of flexible conduit

    I have had a look inside the light to see if the hole can be enlarged, but there is lots of metal moulding on the inside, and the gu10 lampholder is in the way of making a bigger hole, or even a new hole. Also unfortunately the glands can’t be screwed together directly.
  10. J

    How to terminate a cable out of flexible conduit

    In this case there was a fence post 60cm away, so I decided to use that, although I like your idea of using post stumps. That would have been hard for me though because the spike light is in the middle of some garden bushes, and I didn’t fancy crawling around in there! I could swap the metal...
  11. J

    How to terminate a cable out of flexible conduit

    I was thinking of using this at the light end of the conduit.
  12. J

    How to terminate a cable out of flexible conduit

    That’s the back of the light.
  13. J

    How to terminate a cable out of flexible conduit

    It’s an outside spike light. The hole in the light is right at the edge, so the size can’t be increased, and I don’t think I could make another hole, as the base has lots of mouldings that the gu10 lampholder is attached to.
  14. J

    How to terminate a cable out of flexible conduit

    It’s a spike light, and I haven’t found any that look like I could fit a 20mm gland to them. I used the conduit because the 230v flex would run across the ground for about 60cm, so I thought it would be best to protect it a bit with conduit.
  15. J

    How to terminate a cable out of flexible conduit

    Hi I’ve got a flexible plastic conduit coming out of a junction box, where it is terminated with flexible conduit glands. On the other end, a 0.75mm flex cable comes out of it, and goes into a light. The 0.75mm flex is factory fitted to the light, and unfortunately it is not possible to...
  16. J

    Bad electrical design

    Thanks for the explanation, my house has a voltage of 240v, so the amount of voltage drop should be acceptable.
  17. J

    Bad electrical design

    Unfortunately most of the SWA is under the communal parking lot, about 15m, so not much chance of pulling a new cable through. There is also an alarm cable running to the garage with the SWA, so I checked if there was a conduit running to the garage, but there isn’t. Presumably there should have...
  18. J

    Bad electrical design

    It’s probably too late to talk to the developers about that non-compliance:rolleyes:. If I ever get a chance I will replace to cable, but there’s not much I can do about the cable at the moment.
  19. J

    Bad electrical design

    Ok I will go ahead and move the supply to the non RCD side, but just leave it with the B16. I would prefer a larger cable because I would like to run a welder, and have better heating in the winter. Also I have noticed that the lights temporarily dim when I use my mitre saw or other high power...
  20. J

    Bad electrical design

    Hi I’ve got a new build house (2006), which I’ve moved into recently. It has a 16th edition Wylex split load board, and currently the 2.5mm SWA supplying the garage is on a B16 MCB, on the RCD side of the board. At the garage end, there is a garage consumer unit, with an RCD, and B6 MCB for the...