  1. leakydave

    Possible seized pump?

    You need to set the oil pressure and air intake to give the correct co2 reading... a burner can soot up in hours if its not done properly. Don't leave it running like this for too long.
  2. leakydave

    Timed shower

    Intatec Timed Control Valve could work but would have to be blended before the new valve. Best to take the lock off the door so they have to be quick so as not to be disturbed. My sister cannot get her 15 yr old son into the shower!
  3. leakydave

    Soil Stack / Vent Pipe question

    Can you fit a dergo valve on the inside of the bathroom about 300mm above the highest outlet (basin?)?
  4. leakydave

    Bizarre - Central Heating requires Hot Water to be active

    iFlo was a trade name used by City Plumbing/Travis Perkins and is a Drayton Valve I believe.
  5. leakydave

    Curved Radiator source

    http://www.asaluk.com/Bay_window_radiators.html
  6. leakydave

    unvented cylinder - basement

    Should you need to do any maintenance at a later, ie change immersion, date how are you going to drain it?
  7. leakydave

    Worcester 24CDI BOILER PROBLEM

    Mess about with it yourself and there may not be a wedding!
  8. leakydave

    Condensate pipe dripping

    The Worcester OIL boilers constantly drip water... you didn't state if this one was Gas or Oil. Certainly Worcester rate their boilers better than a lot of us do.
  9. leakydave

    measuring heating fuel left in tank

    Or one of these to give you an accurate indicator of the height. It save dipping with a cane or try to see the level on a sight tube. http://www.ebay.co.uk/itm/Watchman-Sonic-Ultrasonic-Oil-Level-Monitor-Home-Heating-Tank-Indicator-gauge-/291177598066?hash=item43cb898c72:g:E3QAAOSw~CRTrB~c...
  10. leakydave

    Need to know everything about tap tails...

    Tap tails max 60°C... central heating could be up to 80°C. Flexible couples would look awful. Do it properly with copper pipe.
  11. leakydave

    Moving soil pipe vent out from building by 50mm

    Dergo Valve? Would that cut down on the need for such a high vent pipe?
  12. leakydave

    Where on earth is the bleed valve?

    A photo of the top of each end of the radiator would be more useful.
  13. leakydave

    Hudson Reed shower valve

    I have changed a few thermostatic cartridges on Hudson Reed Showers to successfully cure the shower running too cool.
  14. leakydave

    Hudson Reed shower valve

    What provides your hot water? Combi or Cylinder? You could try a new thermostat. Ultra does the Hudson Reed spares: 01282 446789
  15. leakydave

    Bar Shower Valve with Top Connection?

    A customer of mine has a faulty bar shower and I cannot identify the right thermostatic cartridge for it and nor can The Shower Doctor. Do any of you know a make of bar shower that has a central ¾" connection on the TOP so I can do a direct replacement with what is already there? Both Mira and...
  16. leakydave

    Removing Danfoss TRV cover??

    Photo would help...
  17. leakydave

    Replacement Radiator top grill clips

    Contact the manufacturer as they will all be different for each make/style of radiator.
  18. leakydave

    Switch heads on bath tap

    Do the indices unscrew? Try moving with rubber gloves on.
  19. leakydave

    Can a "block" be put on an oil tank to prevent use?

    Pipe could be cut and capped off, so can also be uncapped and reconnected.