Search results

  1. J

    13x7 ft Concrete Shed Base over Tree Roots

    The right answer is take them out and do it correctly, you are going to all the effort of laying a concrete base it would be a shame to do anything less … concrete does not stick to wood and that area will always be a week point especially in frost. If you chose to leave them I’d definitely put...
  2. J

    Wago connectors can they be used here?

    Thanks everyone for the clarification Jake
  3. J

    Wago connectors can they be used here?

    Secure thanks for your reply … exactly what you have said !
  4. J

    Wago connectors can they be used here?

    Efl thanks for your reply … I did consider that but trying to squeeze three cables in the back seemed a bit of a squeeze lol
  5. J

    Wago connectors can they be used here?

    Hi Firstly apologies for the rubbish diagram … not easy drawing free hand on a phone lol Key Green fused spurs… 13A mains in , 3 amp lights Orange - Wago connector Blue - sockets Red - mains live Is it possible or should I say acceptable to have a mains live coming into a 13Amp spur...
  6. J

    Hole in cast iron pipe for condensate pipe

    Hi Rob , I'll bow to your experience in this one ... I've had quite a few dealings with cast iron and wielding however I never mix the two ... That said black Smith's are a dying trade and what they can do with metals is nothing less than amazing ! I probably don't use this approach because...
  7. J

    Hole in cast iron pipe for condensate pipe

    Mad rab What I’m on about is welding it the high carbon content would not allow it to be welded with a tig or mig welder , that’s why when it’s made it in a cast .Obviously you can cut it out joints in and out mechanical fixings on as I mentioned however you have the risk of cracking cast iron...
  8. J

    Hole in cast iron pipe for condensate pipe

    He is right cast iron can’t be repaired you would cut it at floor level add an adapter then replace the soi pipe with a modern material. If the hole isn’t too big you could get a mechanical boss strap and a blanking plug.
  9. J

    Stopcock Replacement

    Sounds like you mean an iso valve? That’s the wrong valve for the wrong job. If the other main water valve isn’t leaking and is open leave it and remove the handle , then if there is space put a new stopcock just above it. You would need to turn the water off on the street first. Best wishes Jake
  10. J

    Toilet dripping water into pan

    Gaz I’ve just replied on your other thread I thought you meant when you flush it was leaking externally , on those symphonies the seal Is internally that it passes , the old days you had an over flow now the overflow is the syphon … the easiest way for a diy is to get the same syphon if still...
  11. J

    Replace geberic washer??

    The pic where you have removed the syphon that washer won’t be the cause if it leaks when you flush it will Be the doughnut not the syphon, apologies if I’m getting the wrong side of what you are saying
  12. J

    Replace geberic washer??

    Gaz, The last pic is an iso valve … the flat screw should be pointing vertically if you turn it horizontally it cuts off the water supply. Inside the iso there will Be a fibre 1/2 washer I’d suggest replacing this when re fitting the toilet … the iso valve will disconnect from the cistern at...
  13. J

    Which adaptor needed for connecting countertop dishwasher hose to tap?

    Morning Bright eyes, Hope you are well this fine morning … I hope I can bring some clarity to your last message :) Many things that are on the market work however it’s a diy temporary fix:). Some examples of this would be the outdoor tap kits that have a little bit of hose pipe in the kit ...
  14. J

    Which adaptor needed for connecting countertop dishwasher hose to tap?

    Mad I was thinking the same as you from the 80’s for a make do shower ! I just can’t help but feel anything tan connecting it to the main supply would be a bodge, I don’t think I would actually fit it to a tap for any of my customers
  15. J

    New Toilet on different wall to main Stack

    Morning Fergus, Yes your spot on, when the pipe is laid in the ground it just needs covering with pea gravel before re filling the hole… in relation to finding the best route for the underground pipes I tend to just roughly lay them out and see what works best. I personally think this Is the...
  16. J

    Which adaptor needed for connecting countertop dishwasher hose to tap?

    If i.was.usually installing a dishwasher id use one of these valves... Which.fits a 3/4 hose... You haven't mention.what tap you have however the manufacture will tell you what thread the tap.thread is...its not a critism more of a question but why not fit it direct to your supply. The valve...
  17. J

    New Toilet on different wall to main Stack

    Yep you got it ! The fall of the pipe is taken care of mostly under the ground so you don't have to worry about getting the right fall through your floor boards etc...not a good idea to have a soil stack under the floor I'm assuming your old soil stack will be cast iron? Which if it is won't be...
Back
Top