  1. C

    Radiator not heating up

    Give the pin a few light taps, the valve is stuck on its seat.with the seal back in place .
  2. C

    Sealing up cold breezes

    Yes it looks like they didn’t seal when they put the safety pipe through,
  3. C

    Toilet flush replacements on older toilet

    Yes it’s a standard set up,Tomas Dudley from screwfix
  4. C

    One cold room in the house

    My mate has one of the rad fans that sit on top of the rad and raves about it,I believe you a get ones that fit to the bottom of the rad as well.
  5. C

    F1 error in Ideal Independent C24 boiler

    The two black ones on the silver braided hose
  6. C

    One cold room in the house

    You are correct ,remove the cover and rearrange the furniture to air can flow around the room.A small dehumidifier would also help, and the added benefit of cleaner air .
  7. C

    gas boiler

    Did you isolate the power to the boiler ? Some don’t have low pressure cut off and it may have run dry ,knackering the pump.
  8. C

    Heat exchanger possibility?

    Yes ,plate heat exchanger
  9. C

    Flooded Patio |

    Could you dig a soak away
  10. C

    gas boiler

    Has it a code showing ? Might of over heated what make and model
  11. C

    Tall rad not working (has never worked well), suspect lockshield valve?

    Anti clockwise to open, some vertical rads need a baffle fitting or are directional have you the make of the rad
  12. C

    Changing the AAV

    After checking your pump settings are correct I would cut that “airjack” and alter to a close couple set up easy to alter.
  13. C

    SALUS RXRT505 receiver won't turn on. (No lights)

    Have you tested for 240 v at the receiver ?
  14. C

    Changing the AAV

    Put photos on showing your existing setup.correctly piped it should not have the issues you are describing.
  15. C

    Combi boiler making noise even when no call for heat

    No ,smart thermostatic heads should switch the boiler on/ off ,are yours just opening and closing without switching the boiler
  16. C

    Combi boiler making noise even when no call for heat

    Sounds like the boiler is only switching off because it’s hot,so pump stays running,is it not wired so the valve heads switch boiler on,off rather that the valves just opening .
  17. C

    Bungalow with single upstairs radiator piping question

    It could be removed ,your boiler may require a bypass but a auto one fitted correctly would be needed
  18. C

    High pitched whine that rises and falls for hours after central heating has been on

    Try turning cold water off to the property ,when its doing the noise
  19. C

    High pitched whine that rises and falls for hours after central heating has been on

    I would be looking to see if your pump is switching off after the heating has switched off or your system needs a by pass fitting.
  20. C

    Replacing a thermostat?

    I would replace both parts at that age,simple enough to replace.