  1. P

    Sirrus mixer shower, water still running when shut off

    Your best source for advice will be showerdoc.com See https://www.showerdoc.com/sirrus-ts-1503-thermostatic-shower-valve-shower-spares?srsltid=AfmBOopjGhzg2YTrnZHKq0tm4XQoMhyiBmA0DgI2ovjZVT2jsxAvw5UW
  2. P

    Danfoss p5000si inbuilt obsolescence?. Hard wired button battery at low 1.5v - can't programme!

    As above, simple reset is probably all that is required. https://cdn.expertelectrical.co.uk/media/catalog/product/t/p/tp5000si-instructions.pdf pp24,28 If the unit has failed (less likely but possible) put a link wire between terminals 2 and 3 on the backplate as a temporary override. T2...
  3. P

    Grips

    The Rothys are good. Likewise pretty much anything from Knipex, Nerrad and Bahco.
  4. P

    What waste pipe is this?

    https://www.screwfix.com/p/floplast-wc07-universal-compression-waste-straight-coupler-white-32mm-x-32mm/15490 or elbow
  5. P

    Central heating pipework - 20mm OD Roth Alu-Lazer plus. How to adapt....

    In a word, no. You need a press gun with the right jaws for the fittings. The fittings are specific to the pipe. You might ask Roth who stocks their "Laserrohr" local to you, and then ask that stockist who buys that piping system. That person will have the right gear! Most plumbers won't...
  6. P

    How to schedule DHW production on a Vaillant system boiler without using EBUS ?

    AFAIK what you're trying to do can only be done with Vaillant's own proprietary controls. Happy to be corrected if anyone has achieved this using third party kit.
  7. P

    Change one letter.

    Gimp
  8. P

    Dead bugs and debris coming out of hot water tank.

    As correctly stated above : Black tank is F&E for the water that circulates through the rads, boiler etc. The water that comes out of the hot taps is stored (cold) in in the top part of the fortic, above the annular indentation 2/3 of the way up. OP - what's that top bit of the fortic look...
  9. P

    Kitchen Mixer Tap Fastening Query

    One of these may help: https://www.screwfix.com/p/adjustable-basin-wrench-13mm-40mm/868xr FWIW installer will have fixed tap to sink before fixing sink to worktop.
  10. P

    Dead bugs and debris coming out of hot water tank.

    Are you missing one of these? https://mcdonaldwaterstorage.com/product/alloy-combination-tank-lids/
  11. P

    viessmann outdoor temperature sensor

    Some info, may be relevant to your specific boiler and setup. https://viessmanndirect.co.uk/files//f814ea2a-5b56-4feb-9166-a43e00f71548/WB1B%20Compact%20Outdoor%20Sensor%20Instructions.pdf?srsltid=AfmBOoq4eudAQtJ9P-ie5EtZlJjGAXusjBXmU7iV9P7BzRsPSsfwX-N3 You may need to download software to...
  12. P

    Frost stat heating radiators

    Linking a pipestat in series with a frost stat , both located in the unheated garage is the usual way to achieve frost protection with minimal nuisance triggering. Obviously decent pipe insulation required as well in the unheated space.
  13. P

    power shower question

    Is it a "whole house" pump or is it currently serving one existing shower only?
  14. P

    Kitchen tap head replacement HELP.

    TBH, it's f**ked. Bite the bullet and replace.
  15. P

    Removing old metric radiator

    You'll need two decent sized wrenches; one for the union nut and one for the valve body. You don't want to put any strain on the pipework going up into the valve.
  16. P

    No heating from Danfoss thermostat

    No. Joining the wires has the same effect as setting the programmer to "on", i.e. sending the switching voltage to the thermostat.
  17. P

    Chimney Cowl to use with a gas fire (Ed.)

    Get it checked by a gas safe engineer with the relevant gas fire qualification. At a minimum I would expect him to remove the fire, inspect/clean out the catchment space, carry out a flue test and advise you accordingly. The issue with soot washing down suggests to me that degraded flaunching...