Search results

  1. T

    Black bits out of cold side kitchen tap

    It could be I could swap the flexis? For copper there usually M12 of kitchen taps?
  2. T

    Black bits out of cold side kitchen tap

    I have a tap that has black bits coming out of the cold side of the kitchen tap. If it was the washer breaking down the tap would drip? Any ideas what it maybe?
  3. T

    Capping central heating pipes

    I need to cap some central heating pipes in a boxing. What is best solder if can get rid of all the water? Speedfit or compression? Thanks
  4. T

    Balancing rads lock sheild

    So shut most of the other rads back to only quarter of a turn open?
  5. T

    Balancing rads lock sheild

    Thanks I have some temperature gauges. It's mainly 2 rads on the end of the system that are struggling. I have had all rads of and they get boiling so an air lock isn't an issue
  6. T

    Balancing rads lock sheild

    Is the hope to get 12 degrees across each rad. Does anyone used temp clamps to do it?
  7. T

    Balancing rads lock sheild

    This is a big system 14 rads and underfloor heating. I just wondered how far you are ment to throttle the rads down that are getting hot first.
  8. T

    Balancing rads lock sheild

    All the rads do have trvs
  9. T

    Balancing rads lock sheild

    When balancing rads. Mainly the upstairs to throw more heat downstairs. How far down should you throttle the locksheilds. Is a quarter of a turn open enough? Thanks
  10. T

    Draining down central heating system

    Leak out of the slotted on/off bit?
  11. T

    Draining down central heating system

    Are iso valves really that bad? If fitted on a drop to one radiator. As the internal bore of the rad valve is tiny.
  12. T

    Draining down central heating system

    Pipe rad up and use push fit or compression as last fitting on to existing?
  13. T

    Draining down central heating system

    On the drops the water should stop enough when drained down to solder?
  14. T

    Draining down central heating system

    It's an Splan system maybe Splan plus with the central heating zones.
  15. T

    Draining down central heating system

    Thank you. It does have an auto air vent
  16. T

    Draining down central heating system

    The rads are piped from drops. So thought may not effect the underfloor heating circuit?
  17. T

    Draining down central heating system

    I'm draining to swap a couple of rads downstairs.
  18. T

    Draining down central heating system

    Is there anything different I need to do when draining a central heating system that has underfloor heating on one side downstairs? Also for refilling thanks
  19. T

    Tiling sockets close together

    Thanks would you seal between the sockets with anything?
  20. T

    Tiling sockets close together

    Thanks so no to confirm you wouldn't try and cut a tile for between these two sockets?