  1. E

    Shower trouble

    Recently my shower stopped heating up, was only getting warmish water from it, assumed the thermostat had gone and decided just to replace it so purchased a gainsborough 10.5 deluxe which was pretty much a like for like replacement and now if you turn it up full the water is piping hot however...
  2. E

    rcd question

    board just changed, no testing prior to change and although partp registered certainly not very competent which sort of proves how bad the competent persons scheme is. anyways kitchen appears to be on a ring (new kitchen and apparently kitchen firm did some electrical work) living room and...
  3. E

    rcd question

    to be honest think i would never be able to sort this one, friend rang said he had ran into trouble so i called in and had a quick look. basically ring a is not a ring only one cable in sockets downstairs but 2x 2.5 in 32a mcb at board possibly two radials run from one breaker? i...
  4. E

    rcd question

    neutrals are correctly wired at the board
  5. E

    rcd question

    can anyone help to put the answer to the following into words? on a dual rcd board with sockets up and down on different sides one rcd will trip however if moved so both socket circuits are on one side of rcd the rcd will function correctly explain the reason why the rcd trips?
  6. E

    What Could I Do Next?

    large demand for meter installers at moment and will get bigger in a couple of years when smart meters start to be installed, ok maybe a bit boring but clean, easy work and can make decent money.
  7. E

    Main service fuse

    will get a photo tonight, she is ringing dno for more imformation, but think it may turn into a nightmare for her, no signs of main bonding, no rcd etc etc. There is no rod at property, but a main earth at db 4-6mm which appears to disappear along with supply lines through wall in loft to...
  8. E

    Main service fuse

    darn yes never thought of that, but how from what i can tell there is no sign of earthing rod etc at property, think they are staked at pylons at bottom of streets
  9. E

    Main service fuse

    getting dno to check ze and put 100ma rcd into replace of elcb
  10. E

    Main service fuse

    all test readings came out fine, except there is a d type voltage operated rcd that are outdated now i believe, and its a overhead supply with a ze reading of 229 ohms
  11. E

    Main service fuse

    cant see the size of fuse worn away just said bs88, back of socket was blown checked all fuse wire was right size no tin foil or nails etc.. thought age was a consideration, has to been there since house was built about 70 year ish cant think of anyother reason.
  12. E

    Main service fuse

    what would cause the main bs88 fuse to blow? whilst plugging in a tv there was a bang and electric went off and would not reset. old rewireable fuse type and all fuses were ok but the main service fuse had gone.
  13. E

    dimmer switch woes

    no light is about half bright , then out, then on but flickering. think RF is correct, took dimmer off and replaced with a switch, light was fine, put dimmer in other room with standard bulb, and although not as severe a flicker the bulb does not light fully only dim
  14. E

    dimmer switch woes

    large screw in type, do they come in energy saving type, if so can you tell by looking at them anyway?
  15. E

    dimmer switch woes

    just installed a dimmer switch in bedroom for walllight and although it works, something is not right.. turn on its fine turn up about half way its fine but about half turn and light goes off completely, then as you continue to turn light comes back on but flickers ? help please..........
  16. E

    Smart Meters, who's installing them?

    there is a plan for them to be installed everywhere by 2020 so im told. recruitment companys like rig, vital etc are handling the contracts for uu they just had a recruitment drive for new installers covering the country.
  17. E

    17th complying

    thanks for input, finding it confusing :)
  18. E

    17th complying

    so i can alter or add to a circ in bathroom without providing an rcd but must ensure supp and main bond is ok but if i introduce a new circuit then it must be rcd - is that correct :)
  19. E

    17th complying

    so in that case if i add sockets to a circuit then they dont need rcd, is that right? just found this: If an existing circuit of a location containing a bath or shower is extended, at least the extended part of the existing circuit must be provided with RCD protection. Supplementary bonding...
  20. E

    17th complying

    thanks