  1. L

    Insurance company, heating would not turn on. Won't fix it!

    This would not be classed as an emergency repair,it would be routine maintenence. Emergency means that, water flooding etc. No one could be expected to carry these sort of spares as there are many types,and it can be a good hours job or more if system is old and poorly maintained. I suggest...
  2. L

    Thames Water will not fix the stop cock on the road !!!!!

    Never had a problem getting on street stopcock replaced until last week. We went to a 10 flat property the firm i work for owns that had lost its water supply. We eventually found the stop tap in property which was still on,could not budge plastic one on street with water meter so could not...
  3. L

    Sealing main water feed inside kitchen - Now with images !!!

    The expanding foam will give any rats who get down that pipe a snack before they come into your nice warm well stocked kitchen.
  4. L

    Ideal Classic FF260 Not Firing up

    Ditto dangermouse, pump not circulating enough so gets too hot.
  5. L

    feathers/insulation in cold water tank/down pipe

    Hope he fitted a bylaw 30 kit in the process.
  6. L

    Shower/sink sealant that works!?

    Dow Corning is the one i use,get it from pts. As for applying sealant i think most people put too much on. Get it dry, then use nozzle with a small hole in,dont cut it bigger, then apply, wet finger, usually middle one and run along to smooth out silicone, keep finger wet as it stops it...
  7. L

    Spanish Plumbing

    They are probably(almost definately) connected to the same pipe ,and may have insufficient fall or a partial blockage or undersize pipe or running uphill . :roll:
  8. L

    Poor garden tap pressure

    It would be cheaper to get in a plumber,they are pretty clued up you know.
  9. L

    new radiator warm at top cold at bottom

    Does the pipework for this rad drop down from the floor above or is the pipework coming from below?
  10. L

    unvented cylinder or shower pump?

    If you fit an unvented then you can have a balanced cold which is what you generally take to showers so you have equal hot and cold pressures.But you would know all this if you were qualified , as it stands you would be best getting in someone to advise you further. As you cant boil an egg...
  11. L

    Conversion to a fully pumped system

    You can fit a pump to ch on a primatic but it cannot be made into a fully pumped system, to achieve this a new cylinder and f&e tank will be required. Had this argument with a sparky who told me i must make it fully pumped to comply with building regs, told him he was a tit and unless customer...
  12. L

    Is my pump faulty?(WB24i Junior)

    Brand new to peedee :lol:
  13. L

    Is my pump faulty?(WB24i Junior)

    You answered your own question, it was cleaned and worked for a day, once they are buggered then its best to change them,and all symptoms you mentioned point to pump as boiler is overheating as it cant get the hot water away fast enough. Only other problem is that once it has overheated badly...
  14. L

    Combi Boiler Quote - Fair?

    Its cheap cos its a Heatline, run forest run :lol: Why do you think other guys are busy and cant quote, cos they are decent! Dont wanna scare you but never take the first or the cheapest quote and ask for his corgi id card, if he isnt carrying it then i doubt he is legit. Get 2 more genuine...
  15. L

    mains cold feed to cylinder?

    I have seen it done , with the expansion pipe sealed off and bugger me do you know the cylinder had split causing a bit of a leak below. Not a good idea to make your own unvented.
  16. L

    Placing a Room Stat

    There are lots of back to backs in leeds, the firm i work for owns hundreds but they can be very nice and i suspect because of the fact you have neighbours on 3 sides they should be cheap to heat, just pray you dont have drainage problems. We get so many calls for drains blocking and cellars...
  17. L

    chimney sweep mode

    Are you meaning service mode when you say chimney sweeping mode?
  18. L

    unvented cylinder or shower pump?

    If you need to pump the cold then i doubt you will have an adequate supply for an unvented cylinder,you need to test the flow rate and pressure against manufacturers reccomendations first to ensure your not wasting your money. Plus you must have a relevant qualification to fit an unvented...
  19. L

    combi boiler heating water when cold taps used

    you could fit a non return valve on the cold feed before the boiler which should stop this happening due to pressure fluctuations.
  20. L

    Worcester Bosch v Baxi

    Fitted lots of baxis and i like them, fitted a few wb and thought them a pain in the a%&*. The wb had been changed but not the installation manual !!, Only had one problem baxi duotec, went down after a week with fan, changed next day, then again a week later and baxi fitted a new boiler...