    did u run 22mm in for the cold and 22 to the first hot draw off?
  2. C

    wb 440

    has anyone fitted a wb440 we have a job with it on the building spec. have read mi and understand it but never fitted one, how does it compare to the valliant 937 ecotec plus? cheers.
  3. C

    Boiler Hot Water Output

    did they test the incoming mains water pressure ?i would also test the inlet gas pressure, this unit requires 3.1m3h so if it is in the loft i might exspect to see 28mm gas pipe at the meter ,also check the operation of the govenor.
  4. C

    So CORGI is going

    all the inspectors are changing over to capita
  5. C

    hot water scalding, but house not heating past 15 degrees

    get an rgi to measure your rooms and calculate your rad sizes ,you can spend as much as u like on controls it will not make your house any warmer if the rads are too small, old stelrads spring to mind.
  6. C

    suggestions for toilet pan / soil pipe connector

    is it lead? if so chisel out the plaster/wall under the pipe and dress it into the right position and use a pan connector
  7. C

    Worcester not providing warranty if boiler installed in loft

    nothing wrong with main boilers either
  8. C

    Old lead pipe for WC connection

    give u a clue: lead pipe is a soft material
  9. C

    New Shower Installation

    seperate,
  10. C

    Fitting a shower pump- where to get the cold feed?

    no it doesnt ,it eqalises high pressure to what ever the low pressure supply is by means of an equalibriam valve
  11. C

    New Shower Installation

    use a dedicated shower trap into a gully/hopper you can clean it from inside the shower does not need any other acess.
  12. C

    Fitting a shower pump- where to get the cold feed?

    if you have enough hot water pressure to run your shower use a p e v of the mains water
  13. C

    Fitting a shower over the bath

    just double check it is an unvented cylinder,better to be safe than sorry,
  14. C

    New boiler / system query

    as an installer it is easier to go combi,with open vented and gravity circs there is a lot of pipe work mods plus heat only boilers tend to dearer than combis.
  15. C

    New combi system now my mixers wont work.

    check hot and cold are the right way round ,especially at the showers!
  16. C

    Upgrading incoming main

    ps.godisafrenchman ,eric canntonar
  17. C

    Upgrading incoming main

    look at whole house pumps it would mean changing dhwst but might save you money and you could do it easier than unvented/combihttp://www.techflow.co.uk/pdf/Turbo-install.pdf
  18. C

    MAIN 24 HE

    when all else failsread the manual
  19. C

    MAIN 24 HE

    D.H.W. Filters (Fig. 48) 17. If the flow of domestic hot water is diminished, it may be necessary to clean the filters. 18. Initially check the cold water inlet tap filter. 19. Turn the tap off. Undo the blanking cap and remove the threaded bush (Fig. 47). 20. Extract the filter and rinse...
  20. C

    MAIN 24 HE

    9.8 ltrs max @35degrees above incoming mains temp