  1. J

    Worcester 24Si II - Intermittent fault

    If you have turned down the target (rad) temperature by more than the flowtemperature, (which is normally at the targettemp) -5C then the burner will trip and will not refire again until the anti cycle time has elapsed, under normal conditions this only happens if the heating (rad) demand is...
  2. J

    Vaillant F75 - pump or sensor?

    No, but if it jumps up when you press the start button or very shortly afterwards then that would point to the pump actually starting, don't know what increase the boiler needs to restart but would have thought ~ 0.2bar or so.
  3. J

    Immersion heater thermostat water getting into tube

    That immersion appears to have a separate Hi limit stat attached to the Immersion boss?, Are they still making Immersions with this set up, most of the new ones seem to have it incorporated in the control stat?.
  4. J

    Vaillant F75 - pump or sensor?

    Is that your old EcoTec Plus 831?. When (if) the circ pump starts then you should see the pressure increasing by 0.2/0.3bar, also ensure the pressure is ~ 1.3/1.5bar, cold.
  5. J

    Immersion heater thermostat water getting into tube

    I think both types come with integral stats, the top mounted certainly does, the one below is a dual element immersion where the (one) stat switches either element by switching the neutral, the stat pocket length is normally only the length of the short ~ 11ins element so unlikely to foul on the...
  6. J

    Immersion heater thermostat water getting into tube

    Is that (they) top mounted Immersions?, if so, the stat pocket is renewed each time you renew the immersion as its part of it.
  7. J

    Shower Issue (with Pump) - Only kicks in when turning temperature dial back and forth

    If a negative positive head pump then requires I think > 1LPM to close the flowswitch so measure this trickle from the shower head with it in place.
  8. J

    Can my valiant ecotec run just a single radiator?

    I would suggest that getting a, say, single 2kW rad to operate properly with a 37kW Vaillant is a challenge, to say the least. The boiler will refire (or fire) at ~ 65% of its max output, 37*65%, 24kW and the flowtemp must be kept below the targettemp+5C for up to a minute to avoid the boiler...
  9. J

    Loud Buzzing Noise From Cylinder Driving Us Crazy!!!

    Your WB RI boiler should/will have a external circ pump?, can you post details of its make/model/mode/setting and/or a close up photo of its LEDs while running, may be able to reduce its head which might reduce noise level.
  10. J

    Loud Buzzing Noise From Cylinder Driving Us Crazy!!!

    The circulation flow rate through the coil may be too fast, this can be slowed down by installing a (normally) gate valve on the coil return and then throttling this to say a 1/2 to 1 turn open, it may, but only my, help. A corrugated coil is a coil with corrugations, gives better heat transfer...
  11. J

    Can my valiant ecotec run just a single radiator?

    I think the older type 937 have a minimum output of ~ 12kW, enough to satisfy the max whole house heating requirement for many, if so. 12kw minimum, then not a hope IMO of running it, economically or otherwise, with one rad in circuit.
  12. J

    Are Joule Cyclone Air Indirect any good

    Megaflo suffer from air baffle break up, don't know about the others. OSO cylinders do use a internal air bubble but no air baffle, also, the dip tube can be removed and a external expansion installed which gives ~ 10/15% increase in HW storage.
  13. J

    Downstairs heating only working when upstairs is on

    Easiest way to avoid errors is to change one wire at the time, remove one old...replace with one new etc.
  14. J

    Downstairs heating only working when upstairs is on

    If you are happy the the valve head grey& orange wires are terminated correctly then depending on the valve manufacturer, simply opening the valve manually and latching it open will fire the boiler, a Honeywell won't, but a EPH or Danfoss will, not sure re Myson or any others.
  15. J

    Downstairs heating only working when upstairs is on

    This schematic may help, may have been posted allready above??.
  16. J

    Downstairs heating only working when upstairs is on

    I did say to remove the valve head grey and orange wires before testing, maybe should have said "remove from the terminal block"
  17. J

    Downstairs heating only working when upstairs is on

    I take it the (D/stairs) valve is opening but not firing the boiler?, if so then even though a new valve head I would confirm that its micro switch is closing by removing the valve head grey&orange wires and with the M.meter on resistance check for continuity between them, should read maybe...
  18. J

    Once more unto the breach

    Pumped over warm??, are you saying that hot water is being pumped up and over the vent?, if so, blockage somewhere because its impossible (U tube) for that to happen in a combined feed & vent system. What is your present pump's name/model/mode/setting? and what pump are planning to replace it...
  19. J

    CH Pump Problem

    Thats a giant of a 6M (6.4) pump as "good" as a 8M DAB Evosta2or3, I thought that speed2 would be a bit on the noisy side allright so absolutely no downside of running on speed1 as it probably still circulates more than the selectric on speed3. You're lucky you didn't run it on speed3!!. Have a...