    Light Switch Near Sink

    what if no room to have full 300mm clearance? as long as not directly above and 180mm away would that do?
  2. M

    Light Switch Near Sink

    is 300mm away horizontally or vertically or either?
  3. M

    Light Switch Near Sink

    Is there a regulation/requirement for distance of light switch in a kitchen away horizontally/vertically from the endge of a sinbk or draining board?
  4. M

    PIR

    Is it acceptable to use Calculation from Zs to establish R1 + R2 if you note that is howe you done it on a PIR?
  5. M

    Borrowed Neutral

    When Installing RCD or RCBOs for lighting circuits, and it becomes apparent that there is a borrowed neutral between up and down circuits, and the homeowner wont pay for rectifing this or re-decoration. Would it be ok to put both circuits into the one MCB or RCBO? I know its not ideal but if...
  6. M

    Location containing a Shower

    sorry for slow response, yeah no reason why not, how far away would FSUs need to be, and can the be switched
  7. M

    Location containing a Shower

    If a shower is put into a utility room, which has existing socket outlets for the washer and dryer, and the shower falls within the 3m exclsuion zone for sockets, is it right to say that no electrical work can be carried out in the room until current regs, ie no sockets within 3m of shower...
  8. M

    cables near gas pipes

    ok cheers
  9. M

    cables near gas pipes

    Am i right in thinking electric meter box needs to be then?!
  10. M

    cables near gas pipes

    The outside meter cupboard
  11. M

    cables near gas pipes

    Waterproof
  12. M

    cables near gas pipes

    What about earth cable and gas pipe going straight into top of outside WP enclosure, wouldnt it be better if they went into bottom keeping the top waterproof? Is there a regulation on this?
  13. M

    cables near gas pipes

    yeah and it also goes into top of the outside WP box to connect to it, shouldnt it go in underneath to keep IP rating?
  14. M

    cables near gas pipes

    today i seen a 10mm Earth tie-wrapped to main gas pipe, is this aloud? i thought all electric cables had to be min 25mm away from gas pipes?
  15. M

    Gas Bonding

    only ever bonded internally, do the normal no colour ones weather?
  16. M

    Gas Bonding

    why the blue clamp, is that for outside use?
  17. M

    Gas Bonding

    Gas Meter on outside wall, going straight to back boiler, no exposed pipework of actual gas pipe, altough rads etc linked, so where/do you bond to?
  18. M

    Caravan Set Up

    TT system, but that rod is bout 100m from where caravans would be sited
  19. M

    PIR Recomendation Codes

    Is that only if supplementary bonding is in place?
  20. M

    Caravan Set Up

    Ok. Caravan spikes, to supply 4 caravans, do they have 16A or 13A sockets? SWA buried at 500mm supplying spike, does it require RCD? Does the spike have its own earth rod, and the supply from the spike to the caravans use this earth? Any suggestions is appreciated