Search results

  1. Z

    baxi 80e ongoing problems

    whats your pressure on
  2. Z

    baxi 80e ongoing problems

    It could be the pump as it seems to be overheating due to lack of circulation, it may be sludged up and need a powerflush but if it seems to reset after a certain time then the boiler could be to hot and needs the time to cool down and then start up again.
  3. Z

    Why try and belittle people

    I have noticed something i dont like at all on this site. It,s some peoples attitude towards the questions there answering, if someone comes on and asks for advice then just give advice not a reply which tries to belittle people. I have asked for advice on 5 proplems and on 4 ive had smarta...
  4. Z

    Any ideas lads

    I went back today and after fitting a new aps, it is working perfect.I recently got a megger dual m/meter m8000 and after doing part p , im just getting to grips with my new meter, thanks lads
  5. Z

    She called me a genius ,just lucky

    Didnt you get taught to be polite to the superior race (scousers).FULL STOP
  6. Z

    Any ideas lads

    I done that and its not very helpful as the flashing is pointing at the gas valve but how can it be when the h/water is working soundly,and im convinced the flow switch which was blocked with sludge is the source of the proplem but ive changed it and made sure no muck had blocked the new one ...
  7. Z

    She called me a genius ,just lucky

    I was the 4th fitter shed had out to her gloworm condenser conv boiler, it was firing up but after 10 - 20 mins cut out and then it was firing up but cutting out after 2 - 5 min, so i went there at 3 pm and shed had new parts tried g/valve,pump,etc , all no good, so i knocked and seen the...
  8. Z

    Any ideas lads

    Thanks lads, the pump seems ok , its running as if its sound, i didnt say i changed the thermistor (no change) , and the fan is ok on h/water , i dont like just diving in and saying pcb like many do, its ok if youve got all the parts in your van but iff i buy a pcb and it dosent work it might be...
  9. Z

    Any ideas lads

    A worscter 24 i junior 2 years old, h/water ok, no heating , goes through sequence but doesnt fire,then red light comes on flashing , i thought a flow switch would do the job as the old one was full of muck and was blocked , but no joy , so maybe its all sludged up but it should fire at least ...
  10. Z

    apologise to gasguru

    Sooey we know were the MASTER RACE , school i went to was alsop in walton and believe me learning wasnt on the agenda , i think in all the time i was there , we didnt get told much that was very helpful, it was like this, go into class, talk for a bit , then get told to write (if we wanted)or...
  11. Z

    myson apollo 30/50b pilot will not stay lit

    do you know anything about boilers if you do then a t/coupler is quite easy to fit but if you dont , then dont touch
  12. Z

    myson apollo 30/50b pilot will not stay lit

    t/coupler you hope, as if its not that and the o/heat stat is ok then its a gas valve, is the flame a good size , if it is then you will need to get a corgi reg fitter out to fix it
  13. Z

    Old Flu Hole

    About £5, 1 breeze block inside and 6 brick outside bit of s & cement and jobs done
  14. Z

    apologise to gasguru

    One step at a time, eh i am a scouser and when i was in school learning how to write letters and posts were not important, i wish now they were , its just something we never learnt
  15. Z

    baxi combi instant 105E

    oh its leaking i didnt read all of it ,its knackered if its alot of water ,shut it up and get it replaced
  16. Z

    baxi combi instant 105E

    Leave it open so it can automatically vent your boiler if needs be,just leave the cap loose,if you vent your rads then when you fill the system up this needs to be open or your system will start banging and cutting out
  17. Z

    Baxi 80 ECO combination boiler temporary fix - dangerous?

    Sounds like your diverter valve,it shouldnt heat anything up when you do it manually as the pin isnt coming out allowing the water to flow through the valve and get heated up so unless its something different it shouldnt be any use what boiler is it,and is it onh the h/water or h/w and c/h
  18. Z

    HELP NEEDED QUICK

    I had this problem last year and found it was the gas valve which i didnt expect to be the main issue,the o/heat button was also knocking the pilot out but when i renewed the g/valve it was ok
  19. Z

    apologise to gasguru

    I will take my time now lads,instead of rushing,thanks for the advice,zimmers
Back
Top